Wonderware OmronFINS DAServer 2014 1.0.0 Readme

Wonderware OmronFINS DAServer 2014 1.0.0 ReadMe

Last revision: 9/16/2014

This document contains important information about Wonderware® OmronFINS DAServer 2014 1.0.0. Please carefully review this document for known issues in this version and changes, if any, to the OmronFINS DAServer documentation included on this CD.

Wonderware OmronFINS DAServer 2014 1.0.0 ReadMe Information

System Requirements

Installation Information

Known Issues

OmronFINS DAServer Documentation

You can download the Readme file of the previous version(s) at:

https://wdn.wonderware.com/sites/WDN/Pages/Downloads/default.aspx.

System Requirements

Operating Systems

Wonderware OmronFINS DAServer 2014 1.0.0 supports the following Operating Systems:

  • Microsoft Windows Server 2008 R2 SP1 (64-bit) (Standard and Enterprise)
  • Microsoft Windows Server 2012 (64-bit) (Standard and Enterprise)
  • Microsoft Windows Server 2012 R2 (64-bit) (Standard and Enterprise)
  • Microsoft Windows 7 SP1 (32-bit and 64-bit) (Professional, Enterprise, and Ultimate)
  • Microsoft Windows 7 SP1 Embedded (32-bit)
  • Microsoft Windows 8 (32-bit and 64-bit) (Professional and Enterprise)
  • Microsoft Windows 8.1 (32-bit and 64-bit) (Professional and Enterprise)

Notes: Microsoft Internet Explorer 8.0 or later is recommended on the computer where the product is installed. 64-bit Windows 7 and Windows 2008 will be supported on hardware with x86-64 processor architecture. Itanium IA-64 processor architecture is not supported. We recommend that all available Microsoft Windows patches and security updates are kept up to date on systems running DASSIDirect and DIObjects.

Windows Operating System Restrictions

  • Windows 7 and later versions of operating systems do not support NetDDE. See DDE Compatibility for more information.
  • A DDE client and an OPC client cannot simultaneously communicate with a DAServer. SuiteLink is the recommended communications protocol.
  • When accessing a DAServer remotely using the SMC, Network Discovery on both nodes must be enabled.

Software Requirements

  • Wonderware OmronFINS DAServer 2014 1.0.0 incorporates Visual C++ 10.0 SP1, Visual C++ 9.0 SP1 and Visual C++ 8.0 SP1 run-time redistributable components (If these components are not detected on the computer, they are automatically installed).

DDE Compatibility

  • Local DDE is supported ONLY when the DAServer is configured as "Not a Service" and activated from its executable file or launched from InTouch.
  • On Windows 7 and Windows 2008, Local DDE is NOT supported when the DAServer is activated in the System Management Console (SMC).

Hardware Requirements

To run a DAServer, we recommend as a minimum the following hardware configurations:

  • PC with 2 gigahertz (GHz) or higher processor (32-bit and 64-bit) clock speed

    Note: The Intel Itanium processor is not supported.

  • 1 gigabyte (GB) of RAM or higher (512 MB minimum supported; may limit performance and some features)
  • 8 gigabytes (GB) of available hard disk space
  • Super VGA (1024 x 768) or higher-resolution video adapter and monitor
  • CD-ROM or DVD drive
  • Keyboard and Microsoft Mouse or compatible pointing device

When deploying Wonderware OmronFINS DAServer 2014 1.0.0 in a virtualized environment using Hyper-V, additional hardware requirements apply. For more information about Hyper-V system requirements, see the following web site:

www.microsoft.com/hyper-v-server/en/us/system-requirements.aspx.

Hardware and Firmware

  • Information on specific OMRON controller versions and firmware versions tested against Wonderware OmronFINS DAServer 2014 1.0.0 can be found in the Wonderware OmronFINS DAServer 2014 1.0.0 User's Guide.

< top of document >

Installation Information

Before installing Wonderware OmronFINS DAServer 2014 1.0.0, it is strongly recommended that you exit all Wonderware programs, including executable (.EXE) files and services. Detailed installation instructions are included in the DAServer Installation Guide. It is recommended that you read the DAServer Installation Guide prior to beginning the installation process.

In addition to the procedures described in the DAServer Installation Guide, the following installation requirements and other requirements pertaining to the installation and uninstall orders have to be followed:

Installation Requirements

The following installation requirements are prerequisites for Wonderware OmronFINS DAServer 2014 1.0.0 to work properly:

  • Local administrator privileges are required to install a DAServer.
  • If there are previous versions of DAServers installed on the computer, Wonderware OmronFINS DAServer 2014 1.0.0 will detect them and upgrade them. That is, Wonderware OmronFINS DAServer 2014 1.0.0 allows customers to upgrade from previous versions of other DAServers without uninstalling those DAServers. In addition, components that are common to all DAServers on the system, such as the DASEngine and DAServer Manager, will also be upgraded.

    Important: Wonderware OmronFINS DAServer 2014 1.0.0 will not upgrade existing DASOMRONFINS channel and device configurations in any previously installed versions. After you install this version, you must create new configurations according to the instructions given in the Wonderware OmronFINS DAServer 2014 1.0.0 User's Guide.

  • During installation, the UI states that the feature will be installed on the local disk drive. This is not forced, and you can install on a network drive. However, installing on a network drive is not a valid configuration option. Local installation is a requirement.
  • The DAServer requires Microsoft WoW64 emulation component to be available on any 64-bit platform.

Install Order Requirements

The installation for the DAServers and other Wonderware FactorySuite™ products on the same computer must follow the order as outlined. A DAServer must always be installed last.

  • (If required) - InTouch™ 7.11 followed by application of the latest available InTouch patch
  • (If required) - Legacy I/O Servers™
  • DAServer(s)

This installation order will ensure that any differences, which may exist in the common components included with individual product releases, will install and run without version conflicts. In case of any future patch on the installed Wonderware FactorySuite products, follow the particular installation instructions from the patch.

Uninstall Order Requirements

After installing a DAServer on a computer with other Wonderware FactorySuite products, the following applies:

  • If any Wonderware FactorySuite product is uninstalled from the computer, all other Wonderware FactorySuite products must be uninstalled and reinstalled.

Note: ArchestrA ™products, such as InTouch™ 8.0 or greater, do not require any installation/uninstall order with the DAServers.

< top of document >

Known Issues

L00133719:

When switching to an open screen that has several OmronFINS items configured, there is a short delay (2-3 seconds) before the items are updated.

< top of document >

OmronFINS DAServer Documentation

The OmronFINS DAServer documentation set includes the following guides:

  • DAServer Installation Guide. This online Help provides information on installing the DAServer, including options for installing all components of the system or just individual ones. These include the DAServer Manager (including configuration components of the DAServer), the DAServer (including OPC protocol capabilities), and the DDE/SuiteLink Plug-In (for communicating with the legacy Wonderware products). This Help file can be accessed from CD-DASOMRONFINS as Install-Guide.chm.
  • Wonderware OmronFINS DAServer 2014 1.0.0 User's Guide. This guide describes the user interface and functions of Wonderware OmronFINS DAServer 2014 1.0.0.
  • DAServer Manager User's Guide. This documentation describes the runtime Configuration, Diagnostics, and Activation/Deactivation aspects of a Data Access Server (DAServer). These aspects of any DAServer are maintained through the generic component called the DAServer Manager.
  • License Utility Guide. This guide describes how to use the License Utility to install license files and browse valid license files on the network.
  • LogFlag Editor User's Guide. This documentation describes the user interface and functions of the LogFlag Editor utility. This utility can be opened only from the Log Viewer, a part of the System Management Console suite of utilities.
  • Log Viewer User's Guide. This guide provides information about the Logger™ and the Log Viewer snap-in to the System Management Console.

Documents provided in PDF form can be printed; they are available in the CD-ROM directory\UserDocs\English. Also, information included in these guides is provided in online Help, which can be accessed from the Wonderware OmronFINS DAServer 2014 1.0.0 help system.

Viewing PDF Documentation

The documentation describing how to use this product is included on the CD in PDF format. Viewing these guides requires the installation of Adobe's Acrobat Reader. This utility is not included on this CD, but it can be downloaded for free from the Adobe's Web site at the following Web address:

    get.adobe.com/reader/

After downloading the file from Adobe, you must run the executable to install it on your computer. Follow the typical installation routine. After installation, you can either open the Acrobat Reader and select a user's guide from the File menu, or double-click a user's guide on the CD in Windows Explorer.

< top of document >