Wonderware Application Server 3.1 SP2 Readme
Last revision: 12/18/2009
About This Readme
This document adds information about Wonderware® Application Server 3.1 SP2 (Service Pack 2) to the previous Readme files included with Wonderware Application Server 3.1 and Application Server 3.1 SP1.
New in Wonderware Application Server 3.1 SP2
The following are included in this release:- Application Server Alarm Comment Language Switching support
- New operating system support
- New SQL Server version support
- Using Application Server with Windows Server 2008
- OnShow symbol script behavior changes
- Resolved Issues and merged Hot Fixes
Important!
- Before installing Wonderware Application Server
3.1 SP2:
- Ensure that you create good known backups of all Galaxies.
- If you are using an InTouch 10.0 application with ArchestrA Symbols, run the ArchestrA Symbol Analysis and Repair Utility and ensure all issues reported by the utility are addressed.
- Installing Wonderware Application Server 3.1 SP2 automatically undeploys any platform that is currently deployed in the node that is being updated. Changes to the WinPlatform object and other components require any deployed platforms to be redeployed.
- If InTouch 10.x and Application Server 3.x are installed on the same node, they both must be upgraded to Application Server 3.1 SP2 and InTouch 10.1 SP2.
- Once the GR node is upgraded from any prior version to version 3.1 SP2, all run-time nodes hosting InTouch applications must be upgraded both to Application Server 3.1 SP2 and to InTouch 10.1 SP2 (if you are running InTouch applications). You will not be able to deploy or undeploy objects on non-upgraded nodes.
- If the ArchestrA IDE connects remotely to the Galaxy Repository on another computer, apply Wonderware Application Server 3.1 SP2 to both nodes. A remote connection between the ArchestrA IDE and the Galaxy Repository fails if the nodes are at different versions of Wonderware Application Server.
- If you are using SQL Server 2008, you must be sure to select the x86 option during the SQL Server installation. This will install SQL Server in 32-bit mode, which is the only mode supported.
- SQL Server 2008 does not deliver the BUILTIN\Administrators role by default. Application Server has been modified such that it does not depend on this role. During the product installation, you must provide the proper SQL authentication to allow the installer to configure SQL Server for proper access by the Application Server interfaces. A "SQLAdmin" utility also has been provided to allow the SQL Server configuration if necessary after the install.
- You must install Wonderware Historian 9.0 Patch 02 or Historian 10.0 to take advantange of new historian features including time propagation and late data from the Wonderware Application Server to the Historian. These versions also are required to leverage the new Historian configuration options from the IDE.
- The antivirus software exclusions list has been updated. Click this Antivirus Software Exclusions link for details.
- Windows Server 2008 no longer supports the /console switch as a means of setting the remote desktop client (RDC), also known as a console session. Click this Terminal Services link for further information about terminal services behavior changes.
- Using multiple NICs in Windows Server 2008, as with Windows Vista, requires specific configuration. Click this Using multiple NICs in Windows 2008 for further information about using multiple NICs in Windows Server 2008.
Application Server 3.1 SP2 Information
About Application Server 3.1 Service Pack 2 (SP2)
Software Requirements and Compatibility
Using Application Server with Windows Server 2008
Using Application Server with Windows Vista
Upgrading to Version 3.1 SP2 from an Earlier Version of Application Server
Migrating Applications to Application Server version 3.1 SP2
Resolved Issues - Application Server 3.1 SP2
Known Issues - Application Server 3.1 SP2
Application Server Documentation Issues
Application Server Documentation
Application Server version 3.1 SP1 Information
About Application Server 3.1 Service Pack 1 (SP1)
Using Application Server with Windows Vista
Upgrading to Version 3.1 SP1 from an Earlier Version of Application Server
Migrating Applications to Application Server version 3.1 SP1
Resolved Issues - Application Server 3.1 SP1
Known Issues - Application Server 3.1 SP1
Application Server Documentation Issues
Application Server Documentation
Application Server version 3.1 Information
Using Application Server with Windows Vista
Upgrading to Version 3.1 from an Earlier Version of Application Server
Migrating Applications to Application Server version 3.1
Resolved Issues - Application Server 3.1
Known Issues - Application Server 3.1
Application Server Documentation Issues
Application Server Documentation
About Application Server 3.1 SP2
Wonderware Application Server 3.1 SP2 includes the following enhancements and new features:
Application Server Alarm Comment Language Switching support
The alarm comment language switching feature leverages the multi-language interface developed for Application Server in version 3.1. You can export alarm messages contained in objects to a file, translate them, and import them back into the Galaxy for convenient maintenance. Translated alarm comment files must also be imported by InTouch in order to switch languages at run time.
ArchestrA Alarm Control Column Header Language Switching support
The ArchestrA Alarm Client control has been enhanced to support localization of its column headers. Procedures to localize ArchestrA Alarm Client control column headers are the same as those for localizing ArchestrA symbols.
Support for New Operating Systems
Application Server supports new releases of Microsoft operating systems including:
- Windows Vista SP2: Ultimate, Business, and Enterprise editions, 32/64-bit (emulation mode) versions
- Windows Server 2008 SP2: Business and Enterprise editions, 32/64-bit (emulation mode) versions
Support for New Versions of SQL Server
Application Server supports new releases of Microsoft SQL Server including:
- SQL Server 2005 SP2 and SP3: Standard and Enterprise 32-bit versions
- SQL Server 2008 SP1: Standard and Enterprise 32-bit versions
Support for New Versions of .NET Framework
Application Server supports .NET Framework 3.5 SP1, which is required by SQL Server 2008.
Application Server Utilities and Toolkits
Two Application Server utilities, the Database Scrubber Utility and the Galaxy Graphics Analyzer, have been modified to support the new Microsoft technologies. The Application Server Toolkits (GRAccess, MXAccess and ArchestrA Object Toolkit) support the new Microsoft operating systems as well as Microsoft Visual Studio 2008.
Antivirus Software Exclusions
After installing Application Server, configure your antivirus software to prevent archive files from being scanned. Also, antivirus software should not scan files in the following ArchestrA folders:
NOTE:: |
|
C:\Program Files\ArchestrA\*.*
C:\Program
Files\Common files\ArchestrA\*.*
C:\Program Files\FactorySuite\*.* (may not exist
in newer installations)
C:\Program
Files\Wonderware\*.*
C:\InSQL\Data\*.*
C:\Historian\Data\*.*
C:\Documents and Settings\All
Users\Application Data\ArchestrA*.*
From Application Server Platform objects:
- History Store Forward directory: (if not default)
From Application Server Engine objects:
- Checkpoint directory location (if not default)
<InTouch Application folder path> including:
C:\Documents and Settings\All Users\Application Data\ArchestrA\
<SMCLoggerStoragefilepath>.
The default is:
C:\Documents and Settings\All Users\Application Data\ArchestrA\LogFiles\
SQL Server database files of type:
- .mdf
- .ldf
Minimum Hardware Requirements
The following list shows the minimum computer hardware requirements to host Application Server version 3.1 SP2 components on both 32-bit and 64-bit systems. The Intel Itanium2 processor is not supported.
Galaxy Repository (GR) node
- Computer with 2 gigahertz (GHz) or faster processor, 32/64-bit. A multi-core processor is strongly recommended. The Intel Itanium 2 processor is not supported.
- Minimum of 2 gigabytes (GB) RAM. 4 GB RAM or is recommended.
- At least 30 GB of available disk space for a 32-bit operating system; 40 GB for a 64-bit operating system.
- Super VGA (1024 x 768) or higher resolution video adapter and monitor.
- Network interface card.
- CD-ROM or DVD drive for installation.
- Keyboard.
- Mouse or a compatible pointing device.
Development and Application nodes (with and without InTouch application)
- Computer with 2 gigahertz (GHz) or faster processor, 32/64-bit. A multi-core processor is strongly recommended. The Intel Itanium 2 processor is not supported.
- Minimum 1 gigabyte (GB) RAM. 4 GB RAM is strongly recommended.
- At least 30 GB of available disk space for a 32-bit operating system; 40 GB for a 64-bit operating system.
- Super VGA (1024 x 768) or higher resolution video adapter and monitor.
- Network interface card.
- CD-ROM or DVD drive for installation.
- Keyboard.
- Mouse or compatible pointing device.
The hardware requirements for using the Alarm Client and Trend Client at run time are the same as for the InTouch HMI version 10.1 run time. The Windows Vista and Windows 2008 operating systems and SQL Server 2008 impose hardware requirements that may exceed the minimum requirements for Application Server version 3.1 SP1 and 3.1 SP2. If you intend to install Application Server 3.1 SP2 on a computer running Windows Vista, Windows Server 2008, or SQL Server 2008, see the following Microsoft web sites for hardware requirements:
www.microsoft.com/windows/products/windowsvista/editions/systemrequirements.mspx
www.microsoft.com/windowsserver2008/en/us/system-requirements.aspx
msdn.microsoft.com/en-us/library/ms143506.aspx#EE32
Software Requirements and Compatibility
This section describes the operating system, database, and other software requirements to install Application Server version 3.1 SP2, along with product compatibility.
- Operating Systems
- Product Compatibility
- SQL Server Database Requirements
- Other Software Requirements
Operating Systems
- For server components: Windows Server 2008 SP2 64-bit is the recommended operating system for computers running server components.
- For client components: Windows Vista SP2 32-bit or 64-bit is the recommended operating system for computers running client components.
The following table lists the supported operating systems that can be installed on computers running as Application Server development, application, and GR nodes. Development and application nodes are considered to be clients of the server GR node.
Operating Systems | Wonderware Application Server Components | ||
ArchestrA
IDE (Development Node) |
ArchestrA
Run Time (Application Node) |
Galaxy
Repository (GR Node) | |
Windows Server 2008 SP2, Standard, 32-bit | • | • | • |
Windows Server 2008 SP2, Enterprise, 32-bit | • | • | • |
Windows Server 2008 SP2, Standard, 64-bit (emulation) | • | • | • |
Windows Server 2008 SP2, Enterprise, 64-bit (emulation) | • | • | • |
Windows Vista SP2, Business, 32-bit (See Vista Restrictions) |
• | • | • |
Windows Vista SP2, Enterprise, 32-bit (See Vista Restrictions) |
• | • | • |
Windows Vista SP2, Business, 64-bit (emulation) (See Vista Restrictions) |
• | • | • |
Windows Vista SP2, Enterprise, 64-bit (emulation) (See Vista Restrictions) |
• | • | • |
Windows Vista Business (See Vista Restrictions) |
• | • | • |
Windows Vista Business SP1 (See Vista Restrictions) |
• | • | • |
Windows Vista Enterprise (See Vista Restrictions) |
• | • | • |
Windows Vista Enterprise SP1 (See Vista Restrictions) |
• | • | • |
Windows Vista Ultimate (See Vista Restrictions) |
• | • | • |
Windows Vista Ultimate SP1 (See Vista Restrictions) |
• | • | • |
Windows Server 2003 Standard Edition SP2 | • | • | • |
Windows Server 2003 Enterprise Edition SP2 | • | • | • |
Windows Server 2003 Standard Edition R2 SP2 | • | • | • |
Windows Server 2003 Enterprise Edition R2 SP2 | • | • | • |
Windows XP Professional SP3 | • | • | See Note 2 |
Windows XP Tablet | • |
Notes:
- The Windows 2000 Professional, Windows 2000 Server, and Windows 2000 Advanced Server operating systems are not supported for Application Server version 3.1 SP1 or SP2. An error occurs if you attempt to install or upgrade Application Server version 3.1 SP1 or SP2 on a computer running any edition of the Windows 2000 operating system.
- The computer designated as the Galaxy Repository node can run on Windows XP Pro only as a single-node configuration of Application Server. Windows Server 2008 is the recommended operating system for the GR node.
- The Bootstrap, IDE, and Galaxy Repository are supported by the following language versions of Microsoft operating systems: English, Japanese, Chinese, German, and French. The Galaxy Repository is also supported by the English, Japanese, Chinese, German, and French versions of Microsoft SQL Server 2005 and SQL Server 2008.
Product Compatibility
Wonderware Application Server 3.1 SP2 is compatible and can co-exist with the following products:
- Wonderware InTouch HMI 10.1 SP2
- ActiveFactory 9.2
- InTouch CE 10.1
- Wonderware Historian Server 10.0
- Performance Software 3.5
- Wonderware Information Server 3.1
- InControl 7.11 SP2 PO1
- Manufacturing Execution Module 1.0
- InBatch 9.0
- QI Analyst 8.0 SP2 PO1
- SCADAlarm 6.0 SP2 PO1
In some cases, Application Server 3.1 SP2 is supported in newer environments than a compatible product. Application Server 3.1 SP2 has been tested for compatibility with a listed product only in the environments that are supported by that particular product.
SQL Server Requirements
SQL Server Database Requirements
Microsoft SQL Server 2005 with SP2 or SP3 and SQL Server 2008 SP1 are the databases supported by Application Server version 3.1 SP2. You must use the Standard or Enterprise editions of SQL Server 2005 or SQL Server 2008 SP1. Neither the Compact, Express, nor the Workgroup editions of SQL Server 2005 can be used as the Galaxy Repository. Refer to the following section, SQL Server Rights Requirements, for further information.
- SQL Server 2005 SP2/SP3 or SQL Server 2008 SP1 must be installed on the computer designated as the ArchestrA Galaxy Repository node prior to installing Application Server.
- You also cannot install and use Application Server on a computer that has both Microsoft SQL Server 2000 and Microsoft SQL Server 2005 or 2008 installed.
- The Galaxy Repository locks the SQL Server maximum memory usage to 65% of the computer's physical memory.
- TCP/IP must be enabled on the computer hosting a SQL Server 2005 or 2008 database. The TCP/IP protocol setting can be verified from the SQL Server Network Configuration under SQL Server Configuration Manager.
SQL Server Rights Requirements
SQL Server 2008 does not automatically create the BUILTIN\Administrators role as that was delivered in SQL Server 2005. Because of this change to SQL Server, the Application Server 3.1 SP2 installation process will create the necessary operating system user group (aaAdministrators) as well as the necessary SQL Server role. This automated process will provide the rights required to allow operations within the Galaxy Repository without the need for blanket BUILTIN\Administrator rights. The aaAdministrators group must be present and enabled. If you accidentally delete the aaAdministrators group from the Windows operating system, you can run either of two options to restore it:
- Run the Change Network Utility from the Windows Start menu.
- Run the aaConfig SQL Utility from the Windows Start menu.
If you accidentally delete the aaAdministrators group from the SQL Server security logins, you must run the aaConfig SQL Utility to restore it. Refer to the Wonderware Application Server User's Guide, About ArchestrA User Accounts, for further information and procedures about restoring the aaAdministrators group.
Other Software Requirements
The following list describes other third-party software required for Application Server version 3.1 SP2.
- Microsoft .NET Framework 3.5 must be installed on every computer that hosts an Application Server component. The GR node will require .NET Framework 3.5 SP1 if it is being installed with SQL Server 2008 as .NET Framework 3.5 SP1 is a SQL Server 2008 prerequisite. Application Server 3.1 SP2 has been validated with both .NET Framework 3.5 and 3.5 SP1.
- Microsoft Visual Studio 2005 or Microsoft Visual Studio 2008 Microsoft Visual Studio 2005 or 2008 is required only by the MXAccess and GRAccess toolkits distributed with Application Server.
Alarm Client and Trend Client Requirements
The software requirements for
using the Alarm Client and Trend Client at run time are the same as for the
InTouch HMI version 10.1 run time. If you want to trend data from the Wonderware
Historian (formally known as IndustrialSQL Server), version 9.0 or later is
required.
The Trend Client is compatible with the following Wonderware
products:
- InTouch 10.1 and InTouch 10.1 SP2
- Wonderware Application Server 3.1, Wonderware Application Server 3.1 SP1, and Wonderware Application Server 3.1 SP2
- Wonderware Historian 9.0 or 10.0
- ActiveFactory 9.2
- QI Analyst 8.1
Using Application Server with Windows Server 2008
All behaviors and restrictions described under Using Application Server with Windows Vista apply to Windows Server 2008. This section describes additional behaviors and restrictions when using the Windows Server 2008 operating system with Application Server.
Terminal Services Behavior in Windows Server 2008
In a change from Windows Server 2003, Windows Server 2008 no longer supports the /console switch as a means of starting the remote desktop (RDP) client, also known as Session 0 or Terminal Server Console session. In Windows Server 2008, Session 0 is no longer an interactive session, and is reserved only for Windows services. Windows Server 2008 treats all remote connections as remote RDP sessions regardless of /console, /admin, or any other switches used to make the connection.
This impacts InTouch functionality such as Alarm Manager that depends on the Terminal Server Console session. Refer to the InTouch 10.1 SP2 Readme for further information about InTouch applications running in the Terminal Server Console. The impact to Application Server is minimal as most Application Server processes run as services. One impact to Application Server is to carry forward the restriction introduced with the Windows Vista operating system which permits only one alarm provider. While both Application Server and InTouch can be configured as alarm providers, only one alarm provider is supported.
Application Server and InTouch detect when the application is running in the console. In Windows 2008 it implies that the application was started by a user physically at the machine. However, this behavior requires that you disable Fast User Switching in both Windows Vista and Windows Server 2008 operating systems.
To disable Fast User Switching in Windows Vista or Windows 2008, use the following procedure:
- Click Start, then Run, and enter
gpedit.msc
in the text box. Press Enter. - Go to the following location:
Local Computer Policy \Administrative Templates\System\Logon.
- Set Hide entry points for Fast User Switching to Enabled.
- Exit the Group Policy Editor.
By enabling the policy, Administrators hide the Switch User button in the Windows logon, in the Start menu, and in the Task Manager. Note that the Group Policy Editor does not exist in certain editions of Windows Vista. Alternately, you can configure the setting by editing the Registry.
- Click Start, then Run, and enter
regedit.exe
in the text box. Press Enter. - Navigate to the following branch:
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System.
- Create a DWORD (32-bit) Value named HideFastUserSwitching.
- Set the Value data for HideFastUserSwitching to 1.
- Exit the Registry Editor.
Other Windows Server 2008 Restrictions
- Windows Server 2008, as with Windows Vista, does not support DDE or NetDDE. ArchestrA Symbols use the client layer when accessing InTouch tags and appear as a third-party client trying to access WindowViewer as a data server. As a result, ArchestrA symbols cannot communicate with InTouch tags. The use of NetDDE for communication is not recommended.
- Windows Server 2008 security, as with Windows Vista, prevents started Windows services from interacting with desktop objects. This is a User Interface Privilege Isolation (UIPI) issue. From Windows Vista onwards, DDE cannot communicate across the session. Scripts such as WWPoke(),WWExecute(),WWRequest() will not run across the session. You still can run certain functions by using SuiteLink in place of DDE or NetDDE.
Using Multiple Network Interface Cards with Windows Server 2008
The behavior of Windows Vista with multiple NICs configured has carried forward to Windows Server 2008. If you are using multiple network interface cards (NICs) with Windows Server 2008 SP2, you must configure settings so that the firewall does not block remote node access to the Galaxy Repository. See Using Multiple Network Interface Cards with Windows Vista for further information and procedures applicable to Windows Vista and also to Windows Server 2008.
Using Application Server with Windows Vista
This section describes specific restrictions when using the Windows Vista operating system with Application Server and how to configure multiple Network Information Cards on a computer running Windows Vista.
Vista Restrictions
- Application Server version 3.1 SP2 can run under Windows Vista Enterprise, Business or Ultimate editions. The Windows Vista Home Basic and Home Premium editions are not supported. The Windows Vista Business Edition is recommended for use with Application Server.
- You must log on as a Windows Vista administrator to run Application Server version 3.1 SP2. You cannot run Application Server as a Windows Vista standard user or power user.
- The Windows Vista User Account Control (UAC) must be disabled when running Application Server. Refer to Microsoft Windows Vista documentation for instructions to disable UAC.
- When you disable Windows Vista UAC, you must restart the computer before attempting to install the ArchestrA IDE or Wonderware Application Server. A Galaxy connection error occurs if you attempt to install the ArchestrA IDE or Wonderware Application Server and you did not restart the computer after you disabled the UAC.
- Windows Vista does not support a traditional Application Server single-node configuration that includes Wonderware Historian (formerly IndustrialSQL Server).
- The Galaxy Repository is supported on Vista only for a single-node configuration of Application Server. For multiple-node Galaxies, Windows Server 2008 SP2 64-bit is the recommended operating system for the Galaxy Repository node.
- If the computer that hosts the Galaxy Repository runs on Windows Vista, SP2 must be applied to SQL Server 2005 installed on the same computer.
- A computer running on Vista cannot be configured to be an alarm provider and also have InTouch WindowViewer on the same computer configured to generate alarms. Only one of the two will function properly as an alarm provider.
- Windows Vista does not support NetDDE. ArchestrA Symbols that use the client layer when accessing InTouch tags, and appear as a third-party client trying to access WindowViewer as a data server. As a result, ArchestrA symbols cannot communicate with InTouch tags. The use of NetDDE for communication is not recommended.
- Windows Vista security prevents started Windows services from interacting with desktop objects. When Application Server 3.1 SP2 is installed on a computer running Vista, scripts do not run correctly if they include the InTouch ActivateApp() and SendKeys() functions. Windows Vista prevents these functions from interacting with desktop objects to start Windows programs or send keystrokes to these programs.
Using Multiple Network Interface Cards with Windows Vista
If you are using multiple network interface cards (NICs), you must configure certain settings for the firewall or else a remote Vista node cannot connect to the Galaxy Repository node. A connection in Vista is a term used to define a network interface card (NIC), its settings and the settings of whatever the NIC is connected to. Under certain circumstances, the connection on your computer can change if, for example, the IP address on the computer to which you are connected changes. Your computer's connection can be affected by external factors. During computer startup, and each time a connection changes, Vista goes through an "Identifying" process to determine which profile should be assigned to the connection. A profile is a collection of firewall settings that can be applied to a connection. There are three profiles currently defined in Vista: Domain , Public ,and Private.
- The Domain profile is active only when the computer can authenticate with a domain controller on all active interfaces such as LAN, wireless, and VPN. The domain profile may be more or less restrictive than the other two profiles depending on network security policies.
- The Private profile is active whenever the network type for all active network connections on the computer are identified as private networks. The private profile typically is used in a more trusted environment and is less restrictive than the public profile to allow for network discovery.
- The Public profile is active in all other circumstances. The public profile typically is more restrictive than the private profile because the computer often is connected to the Internet in an insecure location. Network discovery and remote access are disabled rather than explicitly blocking specific traffic. Firewall exceptions and rules can be created on any or all of these profiles.
This is important because the OS Configuration utility and the Vista Firewall utility apply their firewall exceptions to the Domain and Private profiles only. As previously noted, you can specify which profile you want assigned to a connection as long as that connection is not a Domain connection. This is done through the "Network and Sharing Center". Click the Network icon located on the right side of the task bar and then click on one of the networks that is shown. You can change a connection from a Public profile to a Private profile. The firewall calls these settings "Profiles" but the network calls them "Location types."
On computers using dual NICs, the first NIC is normally connected to the domain and is assigned the Domain profile automatically. Windows typically assigns the second NIC the Public profile.
The first issue is that your entire computer (all connections) is restricted to the most restrictive of the profiles assigned to any connection. So if the second connection was assigned a profile of Public, none of the firewall exceptions set by the OS Configuration or Vista Firewall utilities will be allowed. The exceptions were set for Domain and Private only, not Public. You must set the second connection to the Private profile for any of the firewall exceptions to work. You want the active profile on the message exchange (MX) NIC to be the profile opened by OS Configuration.
The second issue is that it appears that a restart of your computer, or even a restart of a computer to which you are connected, can change your connection back to the Public profile. Once again the firewall exceptions will not be effective. You'll have to change the connection back to the Private profile after each restart or a restart of the connected computer. To avoid these NIC issues and prevent the "Identifying" process from taking place on a connection and changing the assigned profile, certain items must be present in the definition of the connection. Follow these rules and procedures:
- If you have only one NIC, no action is required. The profiles and firewall rules are automatic.
- To configure two NICs, do the following:
- If the second NIC is not physically connected to anything (that means no wire in it), no action is required. The profiles and firewall rules are automatic.
- If the second NIC is connected, it MUST be configured. Follow the rules for configuring a normal redundancy setup provided in the Wonderware Application Server User's Guide and the accompanying online help.
- Assign the NIC an IP address, subnet mask and gateway address. Typically, these addresses are internal, non-routable addresses. For example, 192.168.1.xx and 10. x.x.x are common addresses of this type.
- A NIC acting as Redundancy Message Channel (RMC) does not require a default gateway. Otherwise, the gateway can be the same as the IP address. Vista and Windows Server 2008 will identify this NIC and assign it a Private profile.
If you do not configure the second NIC, Vista and Windows Server 2008 will assign a profile of Public to this NIC and cause all of the Wonderware product firewall exceptions to be deactivated on all NICs.
- Set a security policy so that Windows Vista and Windows Server 2008 do not re-set the RMC NIC to a Public profile on rebooting the system or changing the IP address. To make the Private profile setting persistent, do the following:
- On the Windows Start menu, click Run.
- Enter and run this command: SECPOL.MSC. The Local Security Settings menu appears.
- Select Network List Manager Policies on the menu tree.
- Select Unidentified Network from the Network Names displayed.
- Right click, then select Properties, and then change the Location type from Not configured to Private.
- Exit the menu and return to Windows.
- If you have more than two NICs, make sure all connected NICs are configured with an IP address.
Installing Application Server
The Application Server Installation Help (Install-AppServer.chm) located in the root folder of the installation CD includes detailed installation and upgrade instructions. Make sure the target computers that you want to install Application Server version 3.1 SP2 components on meet third-party software requirements. You must install Wonderware Historian 9.0 Patch 02 or higher to use time propagation and late data from the Wonderware Application Server to the Historian.
Upgrading to Version 3.1 SP2 from an Earlier Version of Application Server
After the hardware and software requirements are met, including the proper operating system, SQL server and other pre-requisites, you can upgrade to Application Server version 3.1 SP2 from the following versions of Application Server:
- Version 2.1, including all patches and service packs
- Version 2.5, including all patches and service packs
- Version 30, including all patches and service packs
- Version 3.1
- Version 3.1 SP1
Application Server 3.1 SP2 Upgrade Requirements
The following requirements apply when upgrading existing Application Server components to version 3.1 SP2:
- Upgraded IDE/Client nodes cannot connect to a non-upgraded Galaxy Repository (GR) and vice-versa.
- The GR Node will be undeployed before upgrading to Application Server 3.1 SP2.
- Application Server 3.1 SP2 will import a new major version of the WinPlatform object. This will require the running platforms to be undeployed during the upgrade process.
- Winplatform and other related objects on a remote node will be marked as "software update pending".
- A new schema and extension will be added for the alarm comment language switching feature.
- You will not be able to deploy from an upgraded GR node to non-upgraded remote nodes.
Migrating Applications to Application Server Version 3.1 SP2
There is no migration required from version 3.1 to version 3.1 SP2. You can migrate applications from the following earlier versions of Application Server to version 3.1 SP2:
- Version 2.0 Patch 01
- Version 2.1, including all patches and service packs
- Version 2.5, including all patches and service packs
- Version 3.0, including all patches and service packs
GR Node Migration
For versions earlier than 3.1, as listed in the preceding topic, the existing database schema is migrated to the new version 3.1 SP1 schema. For versions earlier than 3.1, as listed in the preceding topic, data from the existing schema is migrated to the new version 3.1 SP1 schema. Configured Wonderware Historian nodes are saved in the new schema. The GR node migration fails if the GR node is used as a run-time node for another GR. No migration is required from version 3.1 to 3.1 SP1.
Resolved Issues - Application Server Version 3.1 SP2
Wonderware Application Server version 3.1 SP2 resolves the following issues. The issues are listed by their Change Request number. Where Change Requests were the result of Service Requests and Hot Fixes, those reference numbers also are included.
Known Issues - Application Server Version 3.1 SP2
This section describes all known issues identified in Application Server Version 3.1 SP2.
L00084306: | StringFromTime() results are different in InTouch and Application Server. InTouch converts a timestamp given in UTC time to local time and returns the result as a string. This function takes Daylight Saving Time into account. The ArchestrA StringFromTime function still returns the time as GMT. Also, if you change the time zone while WindowViewer is running, the new time zone is not taken into consideration for script functions. On restart of the WindowViewer, the new time zone is taken into account for the script functions. This behavior occurs because time zone information is set during the view initialization. |
L00086242: | Unable to connect to test server nodes when using the SuiteLinkDDEClient object and trying to connect to a local server on Windows Vista. Connection is successful to the Windows XP and Windows Server 2003 nodes. The issue does not occur if you put "localhost" in the node name of the DDESuiteLink DI object. |
L00092635: | Application Server 3.1 SP2 will import an alarm comment file for language switching of format Galaxy_ACLSGalaxy1_2058_Alarm_Comments_Untranslated.txt but InTouch WindowMaker doesn't recognize the file. This behavior is as-designed. InTouch will only recognize file format %_AlarmComment.txt . The option to export untranslated comments was provided in Application Server in order to diagnose and verify quickly whether all translations for a specific locale have been done, and to manage or find untranslated alarm messages in large galaxies. This functionality was provided as value added for Application Server, but was not required for InTouch.
|
L00092675: | In the alarm comment run-time language switching feature, the PhraseId can go out of sync in exported files for the same alarm message in different languages. This doesn�t cause problems in exporting or importing alarm messages into the Galaxy, but it can lead to a failure in InTouch to switch the alarm comment language in run time. Alarms for which the PhraseId does not match between the different languages will not switch. Instead of showing the translated message, the default alarm message, in English if the Galaxy was created in English, will be displayed.
The Lang.dll in InTouch has been modified to log a warning in the SMC that the current alarm message does not match across translated languages. The message recommends that you re-export all the languages of the conflicting file from the Galaxy, and re-import them to the InTouch application. The conflicting file name will be part of the message. We recommend that you keep all the translated exported language files in sync. |
L00093428: | On Vista and onwards, the DDE cannot communicate across sessions. This is a User Interface Privilege Isolation (UIPI) issue. For example, with Application Server running in Session 0 as a service, Excel would run in a session other than 0, a User interactive session. In this scenario, DDE is not able to communicate across the session. SuiteLink can work in place of DDE under certain conditions. |
L00093558: | When you upgrade from Application Server version 2.5 to version 3.1 SP1, the following error message appears: "ArchestrA.Configuration.PackageServerNet.PackageServerNet instance not properly disposed." The error message is informational. No action is required. |
L00093559: | The calendar control in the graphic editor is drawn with different size fonts on different operating systems. For example, the sizes shown are different on Windows Server 2003 and 2008 operating systems. The size of the calendar control does not change when you change the font on the Windows Vista operating system. If a symbol with calendar control is saved in a Windows Server 2003 system and then opened in a Windows Server 2008 system, the size changes after export and import. This affects the symbol layout as well. As a workaround, ensure that your operating system themes are consistent in screen resolution, DPI, icon size, and font size settings. |
L00095432: | After Installing ArchestrA products such as InTouch, InTouch CE, Application Server, InSQL, and ActiveFactory 9.2, some DAServers cannot be installed. During the DAServer installation, a Prerequisite Setup Error appears, "Rainbow Sentinel setup failed to complete successfully." The issue does not occur if the DASevers are installed first and then ArchestrA products are installed. This issue will be addressed in future DASevers releases. |
L00095452: | The Reactor_Demo_Application_Server displays name conflict errors while attempting to enable history for several $ReactorSet.Reactor field attributes such as ConcPump and ConcValve. The issue appeared in Application Server version 3.1 which added the capability in the Extensions section to add a description in the history extension. This modification has created a conflict with field attributes and object graphics. |
L00095695: | When using Microsoft SQL Server 2008 Development Edition, the GR service fails to connect and freezes. This issue occurs because the Development Edition of SQL Server, which is not supported by Application Server, does not enable TCP/IP service by default. |
L00095744: | The Microsoft OLE DB provider for Oracle and neither Driver do Microsoft Access[*.mdb] nor Driver do Microsoft Excel[*.Xls] are visible in a Windows 2008 64-bit SP2 Standard Edition operating system with SQL Server 2008 SP1 installed. These drivers are 32-bit drivers and are not visible in a 64-bit system directly from Control Panel, Administrative Tools, DataSources(ODBC). You can create ODBC connections by running C:\Windows\SysWOW64\odbcad32.exe . This is a 32-bit application, which will display 32-bit drivers. This issue does not occur on 32-bit systems.
Microsoft does not provide a 64-bit OLE DB Provider for Oracle. Oracle provides a separate OLE DB Provider for use on 64-bit systems. |
L00097202: | Memory use rapidly grows when running an application that has InputSource changes every 5 seconds (200 UDAs) and BindTo changes every 10 seconds. Due to a synchronous script timeout, the code does not clean up the local indirect created at the time of script execution, which increases the size of the reference table in the LMX and leads to the memory leak.
There are three possible workarounds to stop the memory leak:
|
L00097788: | Existing license CDs have issues running aaLicView.exe in a 64-bit operating system and will not correctly install a license. You must use the license utility installed with the Application Server or InTouch software. |
L00098305: | After upgrading the GR node, a Deploy/Un-deploy attempt on a non-upgraded remote platform undeploys InTouchViewApp and ViewEngine assigned under the non-upgraded Remote platform. |
L00098946 | With Scan on Demand (SOD) enabled, if an item is activated, deactivated, then reactivated it will return the last value available before it was suspended rather than the current live value. This behavior does not occur if SOD is disabled. |
L00099445 | With SQL Server 2008 installed, and Application Server 3.1 SP2 installed (IDE and Boostrap only), attempting to add a Galaxy Repository using Modify, add GR (Add/Remove Programs, Change option) fails as the Add GR option does not automatically run the aaConfigSQL utility. WWCdi and WWPackageServer errors appear in the logger. This occurs only with SQL Server 2008 installed, and only when the initial Application Server installation was performed using a local account.
As a workaround, you can run the aaConfigSQL utility manually prior to running the Modify, Add GR option. |
L00099447 | An object attribute with an input extension referring to another object attribute remains suspended after deployment when used in a script. This behavior only happens if the object attribute has no other references and is deployed to the backup engine with the primary engine undeployed. The workaround is to add a reference to the object attribute, such as adding it to a watch window, to trigger the activation so that its value, timestamp and quality can be posted appropriately. |
L00099472 | On Windows Server 2008 32/64-bit and Windows Vista 32/64-bit operating systems, with Application Server installed from CD media rather than from a network location or local install folder, adding a Galaxy Repository using the Modify, add GR option (Add/Remove Programs) fails to add a GR. Modify fails to find the path to setup.msi. This issue does not occur with Windows Server 2003 SP2.
As a workaround, you can run the Modify option from the CD image with elevated privileges. |
L00099557 | If you create a symbol with two or more custom properties, then modify the values of one custom property in the properties grid, then select the value field of the other custom property to modify it, the second property's value field shows as blank. Any already existing value disappears from the second custom property value field. The value itself is not erased, but is not shown.
As a workaround, reopen the symbol and use the Custom Properties dialog to populate the custom property values. |
Application Server Documentation Issues
The following table lists all documentation corrections to Application Server 3.1 SP2 documentation.
Item | Location of Change | Existing Documentation | Change |
1 | Creating and Managing
ArchestrA Graphics User's Guide (aaGraphics.pdf), "String Substitutions and Language Switching" section, page 426 Application Server Help (IDE.chm), "String Substitutions and Language Switching" topic |
n/a | Add the following text after the first
paragraph: If you perform a first-time string substitution on an embedded symbol in the primary language, that substitution is shown in the secondary languages. You can then perform a substitution in the secondary language to create a string substitution specific to the secondary language. If you perform a first-time string substitution on an embedded symbol in a secondary language, the substitution is also applied to the primary language, because the translated string that previously existed for the primary language is no longer valid. Because the primary language value is changed in the symbol, this string applies to all secondary languages configured. You can then perform a second substitution in the primary language, which will apply to all secondary languages except the ones that have had a specific substitution set. If you perform a string substitution in a secondary language with an existing string substitution in the primary language, the new substitution is applied to the secondary language only. |
2 | Application Server User's Guide (IDE.pdf), p.134 ArchestrA IDE Help (IDE.chm), "Configuring Advanced Communication Management" topic Wonderware Application Server 3.1 Readme, "About this Release", "Advanced Communication Management" section. |
n/a | Add the following NOTE text after the first
paragraph: NOTE: This dependence on the attribute being referenced by a running application is only the case when the attribute subscription is not already active due to configuration for history, alarming, or scripting. For example, if an attribute is configured for history, the subscription to the field device will always be active regardless of what window is active in InTouch, and regardless of whether InTouch is running at all. |
Saving the Date Timestamp as Historical Data
If slow updates for real-time data values are received from an I/O source and an intermittent network disconnect occurs, the timestamp of the first data value of a historized attribute uses the AppEngine's timestamp instead of the source's timestamp. In the following example, in row number 4, the value "30" is sent again to the historian, but the timestamp is the AppEngine timestamp and not the actual timestamp of "2008-11-24 18:50:41.061" when the value of 30 was generated from the I/O source.
DateTime | TagName | Value | Quality | QualityDetail | OPCQuality |
2008-11-24 18:48:30.081 | Realtime_Client.ival | 20 | 133 | 44 | 192 |
2008-11-24 18:50:41.061 | Realtime_Client.ival | 30 | 0 | 192 | 192 |
2008-11-24 18:51:38.666 | Realtime_Client.ival | NULL | 1 | 24 | 0 |
2008-11-24 18:52:06.670 | Realtime_Client.ival | 30 | 0 | 192 | 192 --> Row number 4 |
2008-11-24 18:53:22.988 | Realtime_Client.ival | 40 | 0 | 192 | 192 |
If slow updates for late data values are received from an I/O source and an intermittent network disconnect occurs, the timestamp of the first data value of a historized attribute is modified to maintain the time sequence. In the following example, in row number 4, the value "30" is sent again to the historian, but the timestamp is modified by adding 5 milliseconds to previous timestamp of the NULL data value. Note that a QualityDetail of 704 is stored for the data value in row number 4.
DateTime | TagName | Value | Quality | QualityDetail | OPCQuality |
2008-11-24 18:48:30.081 | Latedata_Client.ival | 20 | 133 | 44 | 192 |
2008-11-24 18:50:53.624 | Latedata_Client.ival | 30 | 0 | 192 | 192 |
2008-11-24 18:50:53.625 | Latedata_Client.ival | NULL | 1 | 24 | 0 |
2008-11-24 18:50:53.630 | Latedata_Client.ival | 30 | 0 | 704 | 192 --> Row number 4. |
2008-11-24 18:53:26.863 | Latedata_Client.ival | 40 | 0 | 192 | 192 |
Application Server Documentation
The Application Server product library consists of a set of Portable Document Files (PDF) located in the UserDocs\English folder of the Application Server installation CD. You need Adobe Reader installed on your computer to view Application Server documentation. You can download the latest version of Adobe Reader from the Adobe Corporation web site:
http://www.adobe.com/products/acrobat/readstep2.html
After installing Adobe Reader, double-click on a PDF file with your pointing device to view the book with Adobe Reader. You can also open a book with the Adobe Reader Open command from the File menu. Application Server installation instructions are located in the root folder of the Application Server installation CD as an online help file. You can view these instructions by clicking the Installation Guide button in the Application Server installation program. Product documentation is also available with Application Server online help.
Documentation Set
The Application Server documentation set includes the following guides:
- Wonderware Application Server User's Guide. Explains configuring and deploying Application Server applications.
- Creating and Managing ArchestrA Graphics User's Guide. Explains how you create and manage graphical symbols using the ArchestrA Symbol Editor within the Integrated Development Environment (IDE).
- Application Server Scripting Guide. Reference for the scripting language in Application Server.
- Object Viewer User's Guide. Explains how to acquire run-time data using the Object Viewer.
- Guide to the ArchestrA Alarm Control. Explains how to configure the alarm control (client) to show current and historical alarms and events in a grid.
- Guide to the ArchestrA Trend Client. Explains how to configure a chart to trend real-time data values.
- Platform Manager User's Guide. Explains how to start and stop system components.
- Galaxy Database Manager User's Guide. Explains how to backup and restore the Galaxy database.
- Log Viewer User's Guide. Explains how to use the Log Viewer utility to determine system diagnostics.
- Log Flag Editor Utility Guide. Explains how to turn on and off certain diagnostics logging messages.
- Wonderware FactorySuite License Utility Guide. Explains how to use the License Utility to manage the license required for the running application.
- Wonderware ArchestrA Protocol Guide. Explains background information on the main protocols used between components of Wonderware products.
- Application Server Installation Guide. Explains information about installing the product.
- InTouch HMI and ArchestrA Integration
Guide. Explains how you can use the ArchestrA Integrated Development
Environment (IDE) to manage InTouch applications so that you can use symbols
you create in the ArchestrA Symbol Editor. This guide is available on the
InTouch HMI installation CD.
Information included in these guides is provided in online Help, which can be opened using the Help menu options in each utility. During product installation, you can choose to install the documentation PDF on your local hard drive.
Searching Application Server Books with Adobe Reader
The Application Server version 3.1 books are delivered as an Adobe PDF package, which provides a master index of all books. Using Adobe Reader, you can simultaneously search for a specific topic across all books that belong to the Application Server product library.
To search for information across all Application Server books simultaneously
Wonderware Application Server 3.1 Service Pack 1 Readme
Last revision: 03/06/2009About This Readme
This document adds information from Wonderware Application Server 3.1 Service Pack 1 (SP1) to the previous Readme file included with Wonderware Application Server 3.1.About Application Server 3.1 SP1
Wonderware Application Server 3.1 SP1 includes the following enhancements and new features:Enhanced Object Import
You can import an object even when it has a lower (earlier) configuration version than an existing object. During the import, you can:- Overwrite objects with the same tagname and codebase as an existing object even if the imported object is older than the existing object
- Migrate base templates with newer or older codebase
- Rename objects with the same tagname but a different codebase
Enhanced Service Pack Installation
The service pack installer has been modified so that it will not require a deployed platform to be automatically removed or the software uninstalled during the upgrade process. Only major upgrades will require a deployed platform to be removed and redeployed.Antivirus Software Exclusions
After installing Application Server, configure your antivirus software to prevent archive files from being scanned. Also, antivirus software should not scan files in the following ArchestrA folders (ensure subfolders of the listed directories are also excluded):C:\Program Files\ArchestrA\*.*
C:\Program Files\Common files\ArchestrA\*.*
C:\Program Files\FactorySuite\*.* (may not exist in newer installations)
C:\Program Files\Wonderware\*.*
C:\InSQL\Data\*.*
C:\Documents and Settings\All Users\Application Data\ArchestrA\*.* From Application Server Platform objects:
- History Store Forward directory: (if not default)
- Checkpoint directory location (if not default)
C:\Documents and Settings\All Users\Application Data\ArchestrA\ <SMCLoggerStoragefilepath>. The default is:
C:\Documents and Settings\All Users\Application Data\ArchestrA\LogFiles\ SQL Server database files of type:
- .mdf
- .ldf
Minimum Hardware Requirements
The following list shows the minimum computer hardware requirements to host Application Server version 3.1 SP1 components.Galaxy Repository (GR) node
- 2 gigahertz (GHz) or faster dual core processor, or a 3 GHz or faster single core processor. A dual core processor is strongly recommended for optimal performance.
- Minimum of 2 gigabytes (GB) RAM. For Galaxies with more than 500 objects, 4 GB RAM is recommended in the GR node.
- 30 GB of available disk space.
- Super VGA (1024 x 768) or higher resolution video adapter and monitor.
- Network interface card.
- CD-ROM or DVD drive.
- Keyboard.
- Mouse or a compatible pointing device.
Development and Application nodes
- 2 GHz or faster processor.
- Minimum 1 gigabyte (GB) RAM. For improved performance 4 GB RAM is strongly recommended.
- 30 GB of available disk space.
- Super VGA (1024 x 768) or higher resolution video adapter and monitor.
- Network interface card.
- CD-ROM or DVD drive.
- Keyboard.
- Mouse or compatible pointing device.
Software Requirements
This section describes the operating system, database, and other software requirements to install Application Server version 3.1 SP1.Operating Systems
- Windows Server 2003 Standard Edition SP2 is the recommended operating system for computers running server components.
- Windows XP SP3 is the supported XP version for this release.
- Windows XP Professional SP3 is the recommended operating system for computers running client components.
Operating Systems | Wonderware Application Server Components | ||
ArchestrA
IDE (Development Node) |
ArchestrA
Run Time (Application Node) |
Galaxy
Repository (GR Node) | |
Windows Vista Business (See Vista Restrictions) | x | x | x |
Windows Vista Business SP1 (See Vista Restrictions) | x | x | x |
Windows Vista Enterprise (See Vista Restrictions) | x | x | |
Windows Vista Enterprise SP1 (See Vista Restrictions) | x | x | x |
Windows Vista Ultimate (See Vista Restrictions) | x | x | x |
Windows Vista Ultimate SP1 (See Vista Restrictions) | x | x | x |
Windows Server 2003 Standard Edition SP2 | x | x | x |
Windows Server 2003 Enterprise Edition SP2 | x | x | x |
Windows Server 2003 Standard Edition R2 SP2 | x | x | x |
Windows Server 2003 Enterprise Edition R2 SP2 | x | x | x |
Windows XP Professional SP3 | x | x | See Note 2 |
Windows XP Tablet | x |
Notes:
- The Windows 2000 Professional, Windows 2000 Server, and Windows 2000 Advanced Server operating systems are not supported for Application Server version 3.1 SP1. An error occurs if you attempt to install or upgrade Application Server version 3.1 SP1 on a computer running any edition of the Windows 2000 operating system.
- The computer designated as the Galaxy Repository node can run on Windows XP Pro only as a single-node configuration of Application Server. Windows Server 2003 is the recommended operating system for the GR node.
- You can run Application Server only on computers running a 32-bit operating system. You cannot run Application Server on a computer running a 64-bit operating system.
- The Bootstrap, IDE, and Galaxy Repository are supported by the following language versions of Microsoft operating systems: English, Japanese, Chinese, German, and French. The Galaxy Repository is also supported by the English, Japanese, Chinese, German, and French versions of Microsoft SQL Server 2005.
SQL Server Database Requirements
Microsoft SQL Server 2005 with SP2 is the only database supported by Application Server version 3.1 SP1. You must use the Standard or Enterprise editions of SQL Server 2005. Neither the Compact, Express, nor the Workgroup editions of SQL Server 2005 can be used as the Galaxy Repository.
- SQL Server 2005 SP2 must be installed on the computer designated as the ArchestrA Galaxy Repository node prior to installing Application Server.
- You also cannot install and use Application Server on a computer that has both Microsoft SQL Server 2000 and Microsoft SQL Server 2005 installed.
- The Galaxy Repository locks the SQL Server maximum memory usage to 65% of the computer's physical memory.
- TCP/IP must be enabled on the computer hosting a SQL Server 2005 database. The TCP/IP protocol setting can be verified from the SQL Server 2005 Network Configuration under SQL Server Configuration Manager.
- The Microsoft SQL Server 2005 login for BUILTIN\Administrators group must be present and enabled.
Other Software Requirements
The following list describes other third-party software required for Application Server version 3.1 SP1.
- Microsoft .NET Framework 3.5 Microsoft .NET Framework 3.5 must be installed on every computer that hosts an Application Server version 3.1 SP1 component. The Application Server installation program halts if .NET Framework 3.5 is not installed on the target computer. A dialog box appears requesting that you install .NET Framework 3.5. If you click Install Prerequisites, the installation program automatically installs .NET Framework 3.5.
- Microsoft Visual Studio 2005 Microsoft Visual Studio 2005 is required only by the MXAccess and GRAccess toolkits distributed with Application Server.
Alarm Client and Trend Client Requirements
The software requirements for using the Alarm Client and Trend Client at run time are the same as for the InTouch HMI version 10.1 run time. If you want to trend data from the Wonderware Historian (formally known as Industrial SQL Server), version 9.0 or later is required.The Trend Client is compatible with the following Wonderware products:
- InTouch 10.1
- Wonderware Application Server 3.1 and Wonderware Application Server 3.1 SP1
- Wonderware Historian 9.0
- ActiveFactory 9.2
- QI Analyst 8.1
Using Application Server with Windows Vista
This section describes specific restrictions when using the Windows Vista operating system with Application Server and how to configure multiple Network Information Cards on a computer running Windows Vista.Vista Restrictions
- Application Server version 3.1 SP1 can run under Windows Vista SP1, Windows Vista Enterprise SP1, Windows Vista Business SP1, or Windows Vista Ultimate SP1. The Windows Vista Home Basic and Home Premium editions are not supported. The Windows Vista Business Edition is recommended for use with Application Server.
- You must log on as a Windows Vista administrator to run Application Server version 3.1 SP1. You cannot run Application Server as a Windows Vista standard user or power user.
- The Windows Vista User Account Control (UAC) must be disabled when running Application Server. Refer to Microsoft Windows Vista documentation for instructions to disable UAC.
- When you disable Windows Vista UAC, you must restart the computer before attempting to install the ArchestrA IDE or Wonderware Application Server. A Galaxy connection error occurs if you attempt to install the ArchestrA IDE or Wonderware Application Server and you did not restart the computer after you disabled the UAC.
- Windows Vista does not support a traditional Application Server single-node configuration that includes Wonderware Historian (formerly IndustrialSQL Server).
- The Galaxy Repository is supported on Vista only for a single-node configuration of Application Server. For multiple-node Galaxies, Windows Server 2003 is the recommended operating system for the Galaxy Repository node.
- If the computer that hosts the Galaxy Repository runs on Windows Vista, SP2 must be applied to SQL Server 2005 installed on the same computer.
- A computer running on Vista cannot be configured to be an alarm provider and also have InTouch WindowViewer on the same computer configured to generate alarms. Only one of the two will function properly as an alarm provider.
- Windows Vista does not support NetDDE. ArchestrA Symbols that use the client layer when accessing InTouch tags, and appear as a third-party client trying to access WindowViewer as a data server. As a result, ArchestrA symbols cannot communicate with InTouch tags. Windows Server 2003 and Windows XP Pro still support NetDDE.
- Windows Vista security prevents started Windows services from interacting with desktop objects. When Application Server 3.1 SP1 is installed on a computer running Vista, scripts do not run correctly if they include the InTouch ActivateApp() and SendKeys() functions. Windows Vista prevents these functions from interacting with desktop objects to start Windows programs or send keystrokes to these programs.
Using Multiple Network Interface Cards with Windows Vista
If you are using multiple network interface cards (NICs), you must configure certain settings for the firewall or else a remote Vista node cannot connect to the Galaxy Repository node. A connection in Vista is a term used to define a network interface card (NIC), its settings and the settings of whatever the NIC is connected to. Under certain circumstances, the connection on your computer can change if, for example, the IP address on the computer to which you are connected changes. Your computer's connection can be affected by external factors. During computer startup, and each time a connection changes, Vista goes through an "Identifying" process to determine which profile should be assigned to the connection. A profile is a collection of firewall settings that can be applied to a connection. There are three profiles currently defined in Vista: "Domain", "Public" and "Private".- The Domain profile is assigned automatically to a connection if a domain controller for the domain to which the computer is a member is found on the connection.
- The Public profile is designed to keep the computer from being visible to other computers on the network. Network discovery is turned off for the Public profile.
- The Private profile is used for a more trusted environment. Network discovery is turned on for a Private profile. Firewall exceptions and rules can be created on any or all of these profiles.
- If you have only one NIC, no action is required. The profiles and firewall rules are automatic.
- If you have two NICs follow the actions below:
- If the second NIC is not physically connected to anything (that means no wire in it), no action is required. The profiles and firewall rules are automatic.
- If the second NIC is connected, it MUST be configured. Follow the rules for configuring a normal redundancy setup. Vista will identify this NIC and assign it a Private profile. If the NIC is not configured, Vista will assign a profile of Public to this NIC and cause all of the Wonderware product firewall exceptions to be deactivated on all NICs. For the NIC to be configured properly, give it an IP address, sub net mask and gateway address. The gateway address can be the same as the IP address. Usually these addresses will be the internal, non-routable addresses like 192.168.0.x or the 10.x.x.x range.
- If you have more than two NICs, make sure all connected NICs are configured with an IP address and default gateway address and have been assigned a profile of private.
Installing Application Server
The Application Server Installation Help (Install-AppServer.chm) located in the root folder of the installation CD includes detailed installation and upgrade instructions. Make sure the target computers that you want to install Application Server version 3.1 SP1 components on meet third-party software requirements. You must install Wonderware Historian 9.0 Patch 02 to use time propagation and late data from the Wonderware Application Server to the Historian.Upgrading to Version 3.1 SP1 from an Earlier Version of Application Server
After the hardware and software requirements are met, you can upgrade to version 3.1 SP1 from the following versions of Application Server:- Version 2.1, including all patches and service packs
- Version 2.5, including all patches and service packs
- Version 3.0, including all patches and service packs
- Version 3.1
Upgrade Limitations
The following limitations apply when upgrading existing Application Server components to version 3.1 SP1:- Before upgrading the GR node, all deployed nodes must be at the same version and there should be no connected clients.
- Before upgrading a visualization node, the InTouchViewApp AutomationObject should be shut down.
- Uploading application run-time changes from a non-upgraded node is not permitted.
- InTouch HMI must be upgraded to version 10.1 if it is installed on the same computer that has upgraded Application Server version 3.1 0r 3.1 SP1 components.
- If Wonderware Historian is installed on the same computer with Wonderware Application Server, you must install Wonderware Historian 9.0 Patch 02 before upgrading to Wonderware Application Server 3.1 or to Application Server 3.1 SP1.
Updating Wonderware Application Server 3.1 with SP1
- Install the service pack on the Application Server nodes after installing the service pack on the Galaxy Repository node.
- Where possible, exit all applications that are running. To avoid potential platform and engine shutdown issues during the patch installation, we recommend the engines and platform be set off-scan then manually shutdown prior to running the installer.
- To install Service Pack 1:
- Open the ArchestrA System Management Console (SMC).
- Expand Platform Manager.
- Login to the Galaxy.
- Select the Platform for which Service Pack 1 is to be installed.
- From the Right pane, select one engine at a time. Engines hosting DI objects should be set off-scan and shutdown last.
- Right-click the engine and set it off-scan.
- Right-click the engine and shut it down.
- Shutdown the platform.
- Exit the System Management Console prior to installing the patch.
- After Service Pack 1 is applied, you will be prompted to restart the system.
- Do not deploy objects marked with software upgrades until the Galaxy nodes have been updated.
- Platforms containing redundant engines must be updated together.
- If InTouch 10.0x and Application Server 3.0x are installed on the same node, they both must be upgraded to Application Server 3.1 or Application Server 3.1 SP1 and InTouch 10.1.
Migrating Applications to Application Server Version 3.1 and 3.1 SP1
There is no migration required from version 3.1 to 3.1 SP1. You can migrate applications from the following earlier versions of Application Server to version 3.1 and 3.1 SP1:- Version 2.0 Patch 01
- Version 2.1, including all patches and service packs
- Version 2.5, including all patches and service packs
- Version 3.0, including all patches and service packs
GR Node Migration
For versions earlier than 3.1, as listed in the preceding topic, the existing database schema is migrated to the new version 3.1 SP1 schema. For versions earlier than 3.1, as listed in the preceding topic, data from the existing schema is migrated to the new version 3.1 SP1 schema. Configured Wonderware Historian nodes are saved in the new schema. The GR node migration fails if the GR node is used as a run-time node for another GR. No migration is required from version 3.1 to 3.1 SP1.Resolved Issues - Application Server Version 3.1 SP1
Wonderware Application Server version 3.1 SP1 resolves the following issues. The issues are listed by their Change Request number:L00079297: | Cannot import objects if the configuration version is older. |
Known Issues - Application Server Version 3.1 SP1
This section describes all known issues identified in Application Server Version 3.1 SP1.L00089272: | When you upgrade from Application Server version 2.5 to version 3.1 SP1, the following error message is shown: "ArchestrA.Configuration.PackageServerNet.PackageServerNet instance not properly disposed." The error message is informational. No action is required. |
L00089829: | When upgrading from Application Server version 3.1 to SP1, if you
install the Service Pack without first manually shutting down all
platforms and engines, you may encounter NMXService shutdown issues and
the following errors might appear in the log: 7901 2/26/2009 10:56:24 AM 4076 4832 Error NmxSvc Unknown error 0xC0000005 (c0000005) raised. 7902 2/26/2009 10:56:24 AM 4076 4832 Error NmxSvc Unknown error 0xC0000005 (c0000005) caught at line 2128 in NmxControler.cpp (in Y:\AAMXCoreDev\src\NmxSvc\). If these errors appear, you may disregard them. No further action is required. We recommend following the steps outlined earlier in this Readme under the heading "Updating Wonderware Application Server 3.1 with SP1". Upgrades from Application Server versions 2.5 and 3.0 to version 3.1 SP1 do not encounter this issue. |
L00089937: | Importing a major version of an object instance that is on a platform which is currently deployed will result in aaPIM logged messages. To resolve the issue, the platform hosting the object must be undeployed to clear the errors. |
L00089942: | When you upgrade from Application Server version 3.1 to version 3.1 SP1, the following warning message appears in the log: "Failed to patch the galaxy." The logged message applies only to Galaxies from Application Server versions earlier than 3.1. No action is required. Galaxies earlier than version 3.1 will be patched upon connection. |
Application Server Documentation Issues
The following table lists all documentation corrections to Application Server 3.1 SP1 documentation.Item | Location of Change | Existing Documentation | Change |
1 | Guide
to ArchestrA Alarm Control, aaAlarmClientControl.pdf, p.113 ArchestrA Alarm Control Help, aaAlarmClientControl.chm, "Alarm Control Properties" |
n/a | The description and syntax of the
ShowGroupByHeader property need to be added to the Alarm Control
Properties section after the ShowGrid property. The following descriptive
content needs to be added: The ShowGroupByHeader property is a read-write Boolean property to show or hide the column grouping label at the top of the run-time Alarm Control in the historical mode. You can set the ShowGroupByHeader property to true to show the label "Drag a column header here to group by that column". |
2 | Guide
to ArchestrA Alarm Control aaAlarmClientControl.pdf p.27 ArchestrA Alarm Control Help, aaAlarmClientControl.chm, "Showing Current Alarms or Recent Alarms and Events" |
For Alarm Controls
hosted by Automation Object templates or instances, you can specify one of
the following alarm queries:
For more information on absolute alarm queries, see Alarm Queries in the InTouch HMI Alarms and Events Guide. |
For Alarm Controls
hosted by Automation Object templates or instances, you can specify one of
the following alarm queries:
For more information on alarm queries, see Alarm Queries. |
3 | Creating and Managing
ArchestrA Graphics User's Guide (aaGraphics.pdf), "String Substitutions and Language Switching" section, page 426 Application Server Help (IDE.chm), "String Substitutions and Language Switching" topic |
n/a | Add the following text after the first
paragraph: If you perform a first-time string substitution on an embedded symbol in the primary language, that substitution is shown in the secondary languages. You can then perform a substitution in the secondary language to create a string substitution specific to the secondary language. If you perform a first-time string substitution on an embedded symbol in a secondary language, the substitution is also applied to the primary language, because the translated string that previously existed for the primary language is no longer valid. Because the primary language value is changed in the symbol, this string applies to all secondary languages configured.You can then perform a second substitution in the primary language, which will apply to all secondary languages except the ones that have had a specific substitution set. If you perform a string substitution in a secondary language with an existing string substitution in the primary language, the new substitution is applied to the secondary language only. |
Saving the Date Timestamp as Historical Data
If slow updates for real-time data values are received from an I/O source and an intermittent network disconnect occurs, the timestamp of the first data value of a historized attribute uses the AppEngine's timestamp instead of the source's timestamp. In the following example, in row number 4, the value "30" is sent again to the historian, but the timestamp is the AppEngine timestamp and not the actual timestamp of "2008-11-24 18:50:41.061" when the value of 30 was generated from the I/O source.DateTime | TagName | Value | Quality | QualityDetail | OPCQuality |
2008-11-24 18:48:30.081 | Realtime_Client.ival | 20 | 133 | 44 | 192 |
2008-11-24 18:50:41.061 | Realtime_Client.ival | 30 | 0 | 192 | 192 |
2008-11-24 18:51:38.666 | Realtime_Client.ival | NULL | 1 | 24 | 0 |
2008-11-24 18:52:06.670 | Realtime_Client.ival | 30 | 0 | 192 | 192 --> Row number 4 |
2008-11-24 18:53:22.988 | Realtime_Client.ival | 40 | 0 | 192 | 192 |
DateTime | TagName | Value | Quality | QualityDetail | OPCQuality |
2008-11-24 18:48:30.081 | Latedata_Client.ival | 20 | 133 | 44 | 192 |
2008-11-24 18:50:53.624 | Latedata_Client.ival | 30 | 0 | 192 | 192 |
2008-11-24 18:50:53.625 | Latedata_Client.ival | NULL | 1 | 24 | 0 |
2008-11-24 18:50:53.630 | Latedata_Client.ival | 30 | 0 | 704 | 192 --> Row number 4. |
2008-11-24 18:53:26.863 | Latedata_Client.ival | 40 | 0 | 192 | 192 |
Application Server Documentation
The Application Server product library consists of a set of Portable Document Files (PDF) located in the UserDocs\English folder of the Application Server installation CD. You need Adobe Reader installed on your computer to view Application Server documentation. You can download the latest version of Adobe Reader from the Adobe Corporation web site: http://www.adobe.com/products/acrobat/readstep2.html After installing Adobe Reader, double-click on a PDF file with your pointing device to view the book with Adobe Reader. You can also open a book with the Adobe Reader Open command from the File menu. Application Server installation instructions are located in the root folder of the Application Server installation CD as an online help file. You can view these instructions by clicking the Installation Guide button in the Application Server installation program. Product documentation is also available with Application Server online help.Documentation Set
The Application Server documentation set includes the following guides:- Wonderware Application Server User's Guide. Explains configuring and deploying Application Server applications.
- Creating and Managing ArchestrA Graphics User's Guide. Explains how you create and manage graphical symbols using the ArchestrA Symbol Editor within the Integrated Development Environment (IDE).
- Application Server Scripting Guide. Reference for the scripting language in Application Server.
- Object Viewer User's Guide. Explains how to acquire run-time data using the Object Viewer.
- Guide to the ArchestrA Alarm Control. Explains how to configure the alarm control (client) to show current and historical alarms and events in a grid.
- Guide to the ArchestrA Trend Client. Explains how to configure a chart to trend real-time data values.
- Platform Manager User's Guide. Explains how to start and stop system components.
- Galaxy Database Manager User's Guide. Explains how to backup and restore the Galaxy database.
- Log Viewer User's Guide. Explains how to use the Log Viewer utility to determine system diagnostics.
- Log Flag Editor Utility Guide. Explains how to turn on and off certain diagnostics logging messages.
- Wonderware FactorySuite License Utility Guide. Explains how to use the License Utility to manage the license required for the running application.
- Wonderware ArchestrA Protocol Guide. Explains background information on the main protocols used between components of Wonderware products.
- Application Server Installation Guide. Explains information about installing the product.
- InTouch HMI and ArchestrA Integration
Guide. Explains how you can use the ArchestrA Integrated Development
Environment (IDE) to manage InTouch applications so that you can use symbols
you create in the ArchestrA Symbol Editor. This guide is available on the
InTouch HMI installation CD.
Searching Application Server Books with Adobe Reader
The Application Server version 3.1 books are delivered as an Adobe PDF package, which provides a master index of all books. Using Adobe Reader, you can simultaneously search for a specific topic across all books that belong to the Application Server product library.To search for information across all Application Server books simultaneously
- Open Adobe Reader.
- Press CTRL+SHIFT+F or select Search from the Edit menu. The Search dialog box appears.
- Type the word or phrase that you want to search for in the Application Server books.
- In the Where would you like to search area, select the option to search all PDF books.
- If necessary, locate the Application Server version 3.1 PDF package located on your Wonderware CD or on a network folder containing copiesoftheApplicationServerPDFbookfiles. Afterproductinstallation,thesefilescanbefoundat:<driveletter>:\Program Files\ArchestrA\Framework\Docs.
- Click Search. Adobe Reader lists the Application Server books that contain a match for your search criteria.
- Click on the links to open the Application Server book to the topic containing the information that meets your search criteria.
Wonderware Application Server Version 3.1 Readme
Last revision: 01/14/2009 This document contains information about Wonderware Application Server version 3.1, including the new ArchestrA Alarm and Trend Clients. Review this document for descriptions of new features, installation requirements, and any known issues.About This Release
Wonderware Application Server 3.1 includes the following enhancements and new features:Advanced Communication Management
Advanced Communication Management minimizes network traffic and CPU usage of a DIObject or DAServer. While the client application is running, scanning for an attribute value is suspended when the owning object no longer appears in the running application. For example, Advanced Communication Management suspends scanning for an object's attribute value when the operator minimizes the application window containing the object. When the operator shows the window containing the object again, Advanced Communication Management resumes scanning and the object's attribute value is updated in the application.Time Propagation
Time propagation preserves the timestamp of process data obtained from source field devices like a PLC or DAServer. The timestamp can be shown from visualization client applications like InTouch. Also, timestamps are associated with the value and quality of data saved to the Wonderware Historian.Improved Alarm Usability
Individual alarms of an object can now be selectively enabled, silenced, or disabled by an operator or a script.- Object-wide disablement prevails over the alarm mode of any individual alarm. For each individual alarm, the object's alarm mode follows the most restrictive setting of either the individual alarm or the entire object.
- Individually disabling one type of alarm has no effect on any other types of alarms in an object. For example, disabling a HiHi Level alarm of an object does not disable the object's Rate of Change alarm.
- Individually disabling an alarm does not propagate downward through the object hierarchy to any other assigned or contained objects. For example, disabling a HiHi Level alarm on Object A does not disable a HiHi Level alarm on contained Object B.
Script Improvements
Two new methods are available for Application Server scripts. The LogDataChangeEvent() method logs application change events to the Galaxy Historian. The SetAttributeVT() method can be used to set the value and timestamp of an object attribute.New History Attributes
From the IDE, you can configure the historical attributes of data saved to the Wonderware Historian. The following list shows the new historical attributes introduced in version 3.1:- Description
- Interpolation type (linear, stairstep, system default)
- Rollover value (counter-mode retrieval)
- Sample count
- Rate deadband
- Swinging door
Support for Late Data to the Historian
Application Server now includes late data support to save historical data that arrives with a timestamp earlier than the Wonderware Historian's current time.Alarm and Trend Clients
The ArchestrA Alarm Client and Trend Client are available from within the ArchestrA Symbol Editor.The Trend Client:
- Plots the real time values of ArchestrA application object attributes and InTouch tags.
- Supports historical data from a Wonderware Historian or from InTouch history files (LGH). However, the Trend Client can operate without these data sources.
- Supports full and cyclic retrieval while getting data from the Wonderware Historian.
- Supports faceplate displays created within the ArchestrA IDE graphics of InTouch version 10.1 or later.
The Trend Client and Alarm Client work with multilingual versions of InTouch applications and Wonderware Application Server. The Trend Client and Alarm Client support the following languages:
- English
- German
- French
- Japanese
- Simplified Chinese
A localization toolkit is available to add support to other languages and it is distributed separately. It also includes a Microsoft Word version of the documentation.
MXAccess Toolkit Enhancements
The MXAccess Toolkit includes new methods to support Advanced Communication Management and time propagation. Also, the MXAccess Toolkit can be used to write applications that can establish a supervisory connection.Antivirus Software Exclusions
After installing Application Server, configure your antivirus software to prevent archive files from being scanned. Also, antivirus software should not scan files in the following ArchestrA folders: (ensure subfolders of the listed directories are also excluded)C:\Program Files\ArchestrA\
C:\Program Files\Common files\ArchestrA\
C:\Program Files\FactorySuite\ (may not exist in newer installations)
C:\Program Files\Wonderware\
C:\InSQL\Data\
C:\Documents and Settings\All Users\Application Data\ArchestrA From Application Server Platform objects:
- History Store Forward directory: (if not default)
- Checkpoint directory location (if not default)
C:\Documents and Settings\All Users\Application Data\ArchestrA\ <SMC Logger Storage file path>. The default is:
C:\Documents and Settings\All Users\Application Data\ArchestrA\LogFiles\ SQL Server database files of type:
- .mdf
- .ldf
Minimum Hardware Requirements
The following list shows the minimum computer hardware requirements to host Application Server version 3.1 components.Galaxy Repository (GR) node
- 2 gigahertz (GHz) or faster dual core processor, or a 3 GHz or faster single core processor. A dual core processor is strongly recommended for optimal performance.
- Minimum of 2 gigabytes (GB) RAM. For Galaxies with more than 500 objects, 4 GB RAM is recommended in the GR node.
- 30 GB of available disk space.
- Super VGA (1024 x 768) or higher resolution video adapter and monitor.
- Network interface card.
- CD-ROM or DVD drive.
- Keyboard.
- Mouse or a compatible pointing device.
Development and Application nodes
- 2 GHz or faster processor.
- Minimum 1 gigabyte (GB) RAM. For improved performance 4 GB RAM is strongly recommended.
- 30 GB of available disk space.
- Super VGA (1024 x 768) or higher resolution video adapter and monitor.
- Network interface card.
- CD-ROM or DVD drive.
- Keyboard.
- Mouse or compatible pointing device.
Software Requirements
This section describes the operating system, database, and other software requirements to install Application Server version 3.1.Operating Systems
- Windows Server 2003 Standard Edition SP2 is the recommended operating system for computers running server components.
- Windows XP SP3 is the supported XP version for this release.
- Windows XP Professional SP3 is the recommended operating system for computers running client components.
Operating Systems | Wonderware Application Server Components | ||
ArchestrA
IDE (Development Node) |
ArchestrA
Run Time (Application Node) |
Galaxy
Repository (GR Node) | |
Windows Vista Business (See Vista Restrictions) | x | x | x |
Windows Vista Business SP1 (See Vista Restrictions) | x | x | x |
Windows Vista Enterprise (See Vista Restrictions) | x | x | x |
Windows Vista Enterprise SP1 (See Vista Restrictions) | x | x | x |
Windows Vista Ultimate (See Vista Restrictions) | x | x | x |
Windows Vista Ultimate SP1 (See Vista Restrictions) | x | x | x |
Windows Server 2003 Standard Edition SP2 | x | x | x |
Windows Server 2003 Enterprise Edition SP2 | x | x | x |
Windows Server 2003 Standard Edition R2 SP2 | x | x | x |
Windows Server 2003 Enterprise Edition R2 SP2 | x | x | x |
Windows XP Professional SP3 | x | x | See Note 2. |
Windows XP Tablet | x |
Notes:
- The Windows 2000 Professional, Windows 2000 Server, and Windows 2000 Advanced Server operating systems are not supported for Application Server version 3.1. An error occurs if you attempt to install or upgrade Application Server version 3.1 on a computer running any edition of the Windows 2000 operating system.
- The computer designated as the Galaxy Repository node can run on Windows XP Pro only as a single-node configuration of Application Server. Windows Server 2003 is the recommended operating system for the GR node.
- You can run Application Server only on computers running a 32-bit operating system. You cannot run Application Server on a computer running a 64-bit operating system.
- The Bootstrap, IDE, and Galaxy Repository are supported by the following language versions of Microsoft operating systems: English, Japanese, Chinese, German, and French. The Galaxy Repository is also supported by the English, Japanese, Chinese, German, and French versions of Microsoft SQL Server 2005.
SQL Server Database Requirements
Microsoft SQL Server 2005 with SP2 is the only database supported by Application Server version 3.1. You must use the Standard or Enterprise editions of SQL Server 2005. Neither the Compact, Express, nor the Workgroup editions of SQL Server 2005 can be used as the Galaxy Repository.- SQL Server 2005 SP2 must be installed on the computer designated as the ArchestrA Galaxy Repository node prior to installing Application Server.
- You also cannot install and use Application Server on a computer that has both Microsoft SQL Server 2000 and Microsoft SQL Server 2005 installed.
- The Galaxy Repository locks the SQL Server maximum memory usage to 65% of the computer's physical memory.
- TCP/IP must be enabled on the computer hosting a SQL Server 2005 database. The TCP/IP protocol setting can be verified from the SQL Server 2005 Network Configuration under SQL Server Configuration Manager.
- The Microsoft SQL Server 2005 login for BUILTIN\Administrators group must be present and enabled.
Other Software Requirements
The following list describes other third-party software required for Application Server version 3.1.- Microsoft .NET Framework 3.5 Microsoft .NET Framework 3.5 must be installed on every computer that hosts an Application Server version 3.1 component. The Application Server installation program halts if .NET Framework 3.5 is not installed on the target computer. A dialog box appears requesting that you install .NET Framework 3.5. If you click Install Prerequisites, the installation program automatically installs .NET Framework 3.5.
- Microsoft Visual Studio 2005 Microsoft Visual Studio 2005 is required only by the MXAccess and GRAccess toolkits distributed with Application Server.
Alarm Client and Trend Client Requirements
The software requirements for using the Alarm Client and Trend Client at run time are the same as for the InTouch HMI version 10.1 run time. If you want to trend data from the Wonderware Historian (formally known as IndustrialSQL Server), version 9.0 or later is required.The Trend Client is compatible with the following Wonderware products:
* InTouch 10.1
* Wonderware Application Server 3.1
* IndustrialSQL Server 9.0 (Wonderware Historian)
* ActiveFactory 9.2
* QI Analyst 8.1
Using Application Server with Windows Vista
This section describes specific restrictions when using the Windows Vista operating system with Application Server and how to configure multiple Network Information Cards on a computer running Windows Vista.Vista Restrictions
- Application Server version 3.1 can run under Windows Vista SP1, Windows Vista Enterprise SP1, Windows Vista Business SP1, or Windows Vista Ultimate SP1. The Windows Vista Home Basic and Home Premium editions are not supported. The Windows Vista Business Edition is recommended for use with Application Server.
- You must log on as a Windows Vista administrator to run Application Server version 3.1. You cannot run Application Server as a Windows Vista standard user or power user.
- The Windows Vista User Account Control (UAC) must be disabled when running Application Server. Refer to Microsoft Windows Vista documentation for instructions to disable UAC.
- When you disable Windows Vista UAC, you must restart the computer before attempting to install the ArchestrA IDE or Wonderware Application Server. A Galaxy connection error occurs if you attempt to install the ArchestrA IDE or Wonderware Application Server and you did not restart the computer after you disabled the UAC.
- Windows Vista does not support a traditional Application Server single-node configuration that includes Wonderware Historian (formerly IndustrialSQL Server).
- The Galaxy Repository is supported on Vista only for a single-node configuration of Application Server. For multiple-node Galaxies, Windows Server 2003 is the recommended operating system for the Galaxy Repository node.
- If the computer that hosts the Galaxy Repository runs on Windows Vista, SP2 must be applied to SQL Server 2005 installed on the same computer.
- A computer running on Vista cannot be configured to be an alarm provider and also have InTouch WindowViewer on the same computer configured to generate alarms. Only one of the two will function properly as an alarm provider.
- Windows Vista does not support NetDDE. ArchestrA Symbols that use the client layer when accessing InTouch tags, and appear as a third-party client trying to access WindowViewer as a data server. As a result, ArchestrA symbols cannot communicate with InTouch tags. Windows Server 2003 and Windows XP Pro still support NetDDE.
- Windows Vista security prevents started Windows services from interacting with desktop objects. When Application Server 3.1 is installed on a computer running Vista, scripts do not run correctly if they include the InTouch ActivateApp() and SendKeys() functions. Windows Vista prevents these functions from interacting with desktop objects to start Windows programs or send keystrokes to these programs.
Using Multiple Network Interface Cards with Windows Vista
If you are using multiple network interface cards (NICs), you must configure certain settings for the firewall or else a remote Vista node cannot connect to the Galaxy Repository node. A connection in Vista is a term used to define a network interface card (NIC), its settings and the settings of whatever the NIC is connected to. Under certain circumstances, the connection on your computer can change if, for example, the IP address on the computer to which you are connected changes. Your computer's connection can be affected by external factors. During computer startup, and each time a connection changes, Vista goes through an "Identifying" process to determine which profile should be assigned to the connection. A profile is a collection of firewall settings that can be applied to a connection. There are three profiles currently defined in Vista: "Domain", "Public" and "Private".- The Domain profile is assigned automatically to a connection if a domain controller for the domain to which the computer is a member is found on the connection.
- The Public profile is designed to keep the computer from being visible to other computers on the network. Network discovery is turned off for the Public profile.
- The Private profile is used for a more trusted environment. Network discovery is turned on for a Private profile. Firewall exceptions and rules can be created on any or all of these profiles.
- If you have only one NIC, no action is required. The profiles and firewall rules are automatic.
- If you have two NICs follow the actions below:
- If the second NIC is not physically connected to anything (that means no wire in it), no action is required. The profiles and firewall rules are automatic.
- If the second NIC is connected, it MUST be configured. Follow the rules for configuring a normal redundancy setup. Vista will identify this NIC and assign it a Private profile. If the NIC is not configured, Vista will assign a profile of Public to this NIC and cause all of the Wonderware product firewall exceptions to be deactivated on all NICs. For the NIC to be configured properly, give it an IP address, sub net mask and gateway address. The gateway address can be the same as the IP address. Usually these addresses will be the internal, non-routable addresses like 192.168.0.x or the 10.x.x.x range.
- If you have more than two NICs, make sure all connected NICs are configured with an IP address and default gateway address and have been assigned a profile of private.
Installing Application Server
The Application Server Installation Help (Install-AppServer.chm) located in the root folder of the installation CD includes detailed installation and upgrade instructions. Make sure the target computers that you want to install Application Server version 3.1 components on meet third-party software requirements. You must install Wonderware Historian 9.0 Patch 02 to use time propagation and late data from the Wonderware Application Server to the Historian.Upgrading to Version 3.1 from an Earlier Version of Application Server
After the hardware and software requirements are met, you can upgrade to version 3.1 from the following versions of Application Server:- Version 2.1, including all patches and service packs
- Version 2.5, including all patches and service packs
- Version 3.0, including all patches and service packs
Upgrade Limitations
The following limitations apply when upgrading existing Application Server components to version 3.1:- Before upgrading the GR node, all deployed nodes must be at the same version and there should be no connected clients.
- Before upgrading a visualization node, the InTouchViewApp AutomationObject should be shut down.
- Uploading application run-time changes from a non-upgraded node is not permitted.
- InTouch HMI must be upgraded to version 10.1 if it is installed on the same computer that has upgraded Application Server version 3.1 components.
- If Wonderware Historian is installed on the same computer with Wonderware Application Server, you must install Wonderware Historian 9.0 Patch 02 before upgrading to Wonderware Application Server 3.1.
Migrating Applications to Application Server Version 3.1
You can migrate applications from the following earlier versions of Application Server to version 3.1:- Version 2.0 Patch 01
- Version 2.1, including all patches and service packs
- Version 2.5, including all patches and service packs
- Version 3.0, including all patches and service packs
GR Node Migration
The existing database schema is migrated to the new version 3.1 schema. Data from the existing schema is migrated to the new version 3.1 schema. Configured Wonderware Historian nodes are saved in the new schema. The GR node migration fails if the GR node is used as a run-time node for another GR.Resolved Issues - Application Server Version 3.1
Wonderware Application Server version 3.1 resolves the following issues. The issues are listed by their Change Request number:L00046232: | In a UserDefined object, the Time Deadband option of a State alarm for a discrete field attribute is similar to the Time Deadband option for an analog attribute in a limit alarm. |
L00049932: | You receive a "Could not resolve reference" error message for a .desc attribute when saving an instance of a UDO object locked at the template level. |
L00051580: | After importing a Galaxy Load in the IDE with a hierarchy of Platforms, RedundantEngine, and Area objects, the backup engine is deleted in IDE and the primary engine icon is replaced with a normal engine icon. A Galaxy Load is performed with the "Replace Entire Instance" option. The "Replace Entire Instance" option only deletes the objects that have no hosted child objects. |
L00054247: | IDE performance slows significantly after you add more than 100 field attributes to a UDO. |
L00057894: | The calculated WinPlatform.CPULoadAvg value is incorrect for a platform running on a computer with a dual core processor. |
L00059983: | Generating an alarm does not populate the user name or full name into the Alarm Record reported to the Distributed Alarm System if the Galaxy is configured for Galaxy Security and a user is logged on. |
L00061480: | When individual bits are manipulated within a field attribute of type integer using a script within the same UserDefined object, only the value associated with one bit gets manipulated instead of all the bits that are changed in the script. |
L00063314: | The Application Server Alarm Priority range is 0 to 999. The InTouch Alarm Priority Range is 1 to 999. When 0 is entered as alarm priority from Application Server, an alarm priority of 1 is actually logged in alarm database and shown in the InTouch AlarmView summary control. |
L00064528: | An object with a reference to "MyContainer" that is renamed and moved between areas loses the binding reference and shows the warning "Could not resolve reference MyContainer.XXX in attribute -XX.XXX". |
L00064546: | An InTouch client application running on a non-upgraded remote node cannot see an alarm generated on another remote node that has been upgraded with Application Server. |
L00066957: | Cannot deploy any object if the computer's Windows DEP configuration is set to /noexecute=AlwaysOn. |
L00067495: | Migrating an Application Server version 2.5 Galaxy with FMM objects fails with errors, and the migration process hangs in an infinite loop. |
L00067697: | A large cascade deploy does not complete because a Redundant engine was stopped by the Bootstrap while it was starting up on a remote node. |
L00068078: | A cascade deploy of over 1000 objects were deployed off scan, but marked as undeployed without error messages. |
L00068433: | If you shut down the Wonderware Historian and then immediately restart the computer, frequent disconnects/reconnects occur for MDAS clients, such as the Wonderware Application Server. This fix requires Wonderware Application Server 3.1 and Wonderware Historian 9.0 Patch 02. |
L00069976: | Application Server scripts calculate Quality incorrectly for expressions containing Boolean AND or OR operators. |
L00070352: | A radio button graphic shows only one button with a title Unresolved Reference the first time the IDE is started. |
L00070995: | Deploying or undeploying a GRPlatform of over 170 remote nodes takes several hours and error messages are written to the log. |
L00071061: | Backing up a large Galaxy fails because of insufficient disk space without a warning message written to the logger. |
L00071079: | When uploading run-time changes for an object with a symbol, the revision version does not remain consistent with the configuration version. |
L00071206: | Users can acquire User Configuration permissions with any security mode. |
L00071647: | The OnShow script in an ArchestrA graphic appears to run, but the script does not set an attribute. (See SR14811879) |
L00071843: | ObjectViewer does not handle a returned WriteStatus of "Pending" properly because it does not wait for the final SetReponse() return message and the dialog box normally shown for writes that fail does not appear. |
L00072015: | When an FSGateway is deactivated on an ApplicationObject server node, the SMC and ObjectViewer become unresponsive, and platform communications are disrupted. |
L00072074: | Communication failures during a cascade deployment of a large number of objects cause the deployment to fail. |
L00072300: | When a client control is deleted and a new version of the client control is imported from a remote IDE, an ArchestrA Symbol referencing the client control will show Version 1 on the remote IDE and Version 2 on the Galaxy Repository IDE. This is a mismatch of versions. (See SR103112086 |
L00072450: | An attribute value from the CheckedInPackage of an object using IGalaxyFX interface cannot be obtained because the Check Out and then Check In operations fail when done for an instance of custom ArchestrA object. |
L00073495: | A Galaxy backup does not work correctly if the ArchestrA IDE is not installed on the same computer. |
L00073550: | The graphic element reference list is incomplete, or it is corrupted. The error message "Failed to get Graphic element reference list" appears in the SMC Logger. (See SR23515471) |
L00074841: | An ApplicationObject fails to deploy when an InternationalizedString Array in the object is modified using GRAccess. |
L00075206: | Customized graphic text is lost after group change.(See SR14811926) |
L00075453: | A WinPlatform object Remote Activation Failure error occurs when you attempt to deploy the object to a node with a name greater than 15 characters. |
L00075663: | When Application Server and Factelligence are installed together, users can successfully log on from the Configure Galaxy dialog box without a valid password or user ID. |
L00075763: | Custom property links for ArchestrA symbols do not accept the following special characters that can be used in InTouch tag names: _ (underscore), - (hyphen), $ (dollar), % - (percent), and &. - (ampersand). |
L00075800: | MX References do not start in scripting; .InputSource in ArchestrA Graphics does not start in scripting. The MX References do work on display the link and in a Custom Property. (See SR15010810) |
L00075917: | A Galaxy load operation that uses the Only Update Changed Attributes option forces all modified objects to a checked out state. |
L00076426: | An exception occurs while checking in a derived template with ArchestrA graphic symbols and more than 1000 instances. |
L00076900: | Warning "Could not find embedded graphics" appears after a template and its instances of a Galaxy are exported as an aaPKG file, and are then re-imported into a new Galaxy. (See SR33430263) |
L00077680: | Watch window does not always update with the current Float Array values after copying values from another Float Array or changing values from the ObjectViewer |
L00078407: | Exporting the contents of the Galaxy Repository fails with warning messages written to the logger. |
L00079430: | Removing a string from a symbol with Value Display Animation in a primary language also removes the strings in secondary languages. |
L00081739: | The Graphic toolbox pop-up window and the Graphics tab preview window thumbnails show "not found" when an application object instance containing symbols with date time picker is imported in a new Galaxy. |
L00087227: | A Wonderware Application Server 3.0 Galaxy with an imported InTouchCompactApp aaPKG file to Wonderware Application Server 3.1, errors are logged in the SMC Logger. |
Known Issues - Application Server Version 3.1
This section describes all known issues identified in Application Server Version 3.1. The known issues are grouped by function.L00069519: | In a redundant load sharing environment, the cascade deployment of a
backup platform does not deploy InTouch ViewApp instances, if the
redundant AppEngine has InTouch proxy objects configured. Backup redundant
object errors are logged. After the InTouch ViewApp deploy fails, it can be manually re-deployed. |
L00076557: | Opening and closing a view window when "Advanced Communication Management" is enabled for the Galaxy may cause a different timestamp to be returned for the attribute from the DAServer, even though nothing has changed on the device. |
L00077487: | During tag registration,
Wonderware Historian discards the value for SampleCount (isSamples)
provided by Application Server. This issue is discussed in CR
L00077833. Before installing Wonderware Application Server, apply Wonderware Historian 9.0 Patch 02 to resolve this issue. |
L00077490: | Importing a client control from a Galaxy imports another version of the same client control if the other version resides in a different Galaxy on the same node. |
L00078221: | After you migrate an Application Server 2.1 application to Application
Server 3.0 or later, the wrong value is returned for the .NET
ToLocalTime() function. Application Server 2.1 supports .NET 1.1, while Application Server 3.0 supports .NET 2.0. The DateTime structure in .NET 2.0 includes a new Kind property that indicates whether the time represents a local time, a Coordinated Universal Time (UTC), or whether UTC or local time is not specified. For more information, see the following Microsoft documentation: http://msdn.microsoft.com/en-us/library/system.datetime.aspx To migrate an Application Server 2.1 application to version 3.0 or higher, you must modify scripts that use the ToLocalTime() function. Use the new Kind property (DateTime.KindProperty) and specify the time before you run the ToLocalTime() function. For example: dim aTime as System.datetime; dim aTime2 as System.DateTime; aTime = me.lastpolltime; aTime = system.datetime.SpecifyKind(aTime, system.dateTimekind.utc); me.locallastpolltime = aTime.tolocaltime(); |
L00078446: | The ArchestrA Symbol Editor stops responding when you edit the "format string" property of the "checked list box" client control. |
L00078465: | Dates earlier to 1970 are not valid for purposes of the
LogDataChangeEvent() script function. Using a date earlier than 1970 sends
a warning message to the logger. Use a date on or after 1/1/1970 when using the "LogDataChangeEvent()" script. |
L00079595: | Attempting to import a client control with the ArchestrA IDE fails if the file is located at a remote network location. Copy the client control file to the local computer where the ArchestrA IDE is installed to import operation. |
L00081837: | The following error message appears when a non-upgraded IDE node (earlier than ApplicationServer 3.0 SP2) tries to connect to an upgraded Galaxy Repository node. Error message: "IDE cannot connect to remote GR node <name> because it is an older version <number> than this IDE version supports." |
L00082886: | Area objects are not
deployed after performing a cascade deploy of a Galaxy migrated from
version 3.0 to version 3.1 of Application Server with Vista as the
operating system. Perform the following as a workaround. 1. Click Start, then Run. The Run dialog box appears. 2. In the Open field, type OptionFeatures.exe 3. Click OK. The Windows Features dialog box appears. 4. Expand the following: * Microsoft message Queue (MSMQ) Server * Microsoft message Queue (MSMQ) Server Core 5. Place a check to the left of: * Microsoft message Queue (MSMQ) Server * Microsoft message Queue (MSMQ) Server Core * MSMQ Active Directory Domain Service Integration * MSMQ HTTP Support *MSMQ Triggers * Multicasting Support * MSMQ DCOM proxy 6. Click OK. The Windows Features dialog box closes. 7. Deploy the Automation Objects. |
L00083270: | Spaces are not imported as part of the translation for the selected language. |
L00083828: | There are inconsistencies between the selected language and the strings that are shown. |
L00083909: | InTouch applications receive Quality Status and Locale information from the deployed Galaxy. InTouch applications cannot receive data from an undeployed Galaxy. |
L00085806: | The font used for graphics in ArchestrA symbols does not render
properly in the Symbol Editor and on print outs, if the DPI of the screen
or printer is less than or greater than 96-dpi. Wonderware does not support running the product in DPIs other than 96 DPI. |
L00086625: | When you upgrade nodes from Wonderware Application Server 3.0 Patch 03 to 3.0 SP2, the following warning from msiexec appears: "GetArchestrAInstallPath(): Failed to Read the Registry ArchestrA install path Key". |
L00087046: | An embedded symbol is lost after swapping symbol names. VERL (Visual Element Reference List) corruption is artificially causing a circular reference. |
L00087247: | InTouchViewApp fails to undo a checkout when there is a file-lock
within the CheckOut folder. You should not attempt to check-in the
InTouchViewApp. Fix the file-lock issue, and perform the "undo-checkout" again. |
L00087305: | When you rename a referenced symbol while an object editor is open, the reference to the renamed symbol may be lost. |
L00087471: | The background reference binding thread may stop processing because of
a database connection failure. The following message is logged in the
System Management Console: "Warning WWCdi CRefString(TagName Validation).
Database connection is no longer valid." You must restart the aaGR.exe process to reestablish the connection to the database server. |
L00087752: | You must restart the aaGR.exe after you import an object with a minor
version increment, if the object is written in .NET. The issue may occur for ApplicationObjects written in .NET with the ApplicationObject Toolkit 3.1, versus ApplicationObjects written with an older version of the ApplicationObject Toolkit. Restart of the aaGR.exe is required if all of the following apply: You must restart aaGR.exe for the new object to be recognized and deployed to the IDE nodes. |
ArchestrA Alarm Client
This section lists current issues that remain in the ArchestrA Alarm Client (Control).L00080966: | Unable to browse all supported methods and properties from the Alarm Control's Element Browser. Also, many additional unwanted methods and properties appear in the Element Browser. This is due to limitation from the ArchestrA framework. Workaround: Use the Guide to the ArchestrA Alarm Control as reference. Chapter 4 "Scripting the Alarm Control" contains all supported methods and properties including syntax and in most cases examples. |
L00082738: | Query filters added at run time are not saved if you switch back to WindowMaker. Workaround: Export the query filters you create at run time to an XML file. After switching back to WindowMaker, import the query filters from the XML file. |
L00084764: | If you change the Query String of the Default Query after adding filtering criteria using the Query Filter editor, then the additional filtering details are removed. |
L00085789: | It is not possible to hide more than 300 single alarm records. If you need to hide a larger number of alarms, consider hiding the group or priority instead. Hiding one group instead of many individual alarm records in that group only creates one hidden item in the Hidden Alarms dialog box. |
L00086092: | It is not possible to hide any alarm records if the alarm query is configured for a large number of providers. If the alarm query is too long, when you attempt to hide alarms, a message is shown in SMC Log Viewer and a message "The maximum limit of hidden alarms has been reached" appears. To avoid this problem, consider using multiple Alarm Controls or switching the alarm query between several sets of alarm providers. |
L00086127: | The scriptable properties and methods to hide alarms continue to
operate when the alarm control is in the historical mode, although the
historical alarms are not hidden. Acting on historical alarms with a hide
request should be avoided. This can cause the control to use excessive
CPU. In the script that hides alarms, set the client mode to "1" or "2" ("Current Alarms" or "Recent Alarms and Events"), before performing a hide action. |
L00088079: | Portions of the Symbol Editor are shown in black when the Embedded Alarm Control - Edit Animations - Colors Configuration dialog box opens. This is observed only on Windows XP and Windows 2003 with Display Properties configured to use the 'Windows XP' Theme. |
ArchestrA Trend Client
This section describes all known issues identified in the Trend Client.
L00082107: | When you import the Trend Client package (.aaPKG) into the IDE, some unwanted warning messages appear in the logger. | ||
L00085245: | When you configure the Pen Type (Pen.TrendType)as 'Auto' and the default value of Historian is not available,the Trend Client generates Plot type as line during run time, regardless of the data type (real or integer). | ||
L00086210: | If you use a relative reference for a custom property in the pen configuration, the Trend Client does not resolve the pen configuration during run time. The Trend Client supports custom properties for absolute references, but does not support custom properties for relative references. | ||
L00086285 : | The Trend
Client does not copy any background image files to another node and,
therefore, does not show a configured plot image on a client node. To view
the plot image on a client node:
| ||
L00087611: | The Element Browser or Events page of the Trend Client shows a number of unwanted events and properties. Also, the Element Browser or Events page does not allow you to browse all the supported methods, properties, and events. This occurs because of a limitation of the ArchestrA framework. For information about all the supported methods, properties, and events, see the Trend Client documentation. | ||
L00087617: | The AddPen method does not work when you specify a relative reference or an absolute reference as a history source name. You must specify the value for the history source name in the script if you add a pen using a script. | ||
L00087683: | A data loss occurs when you initialize the trend with history data and refresh the trend chart. |
Application Server Documentation Issues
The following table lists all documentation corrections to Application Server 3.1 documentation.Item | Location of Change | Existing Documentation | Change |
1 | Application Server User's Guide, IDE.pdf, "Saving the Date Timestamp as Historical Data," page 154. Application Server Help, IDE.chm, "Saving the Date Timestamp as Historical Data" topic |
n/a | Add the following paragraphs for "Saving
the Date Timestamp as Historical Data" after the last paragraph:
|
2 | Guide
to ArchestrA Alarm Control, aaAlarmClientControl.pdf, p.113 ArchestrA Alarm Control Help, aaAlarmClientControl.chm, "Alarm Control Properties" |
n/a | The description and syntax of the
ShowGroupByHeader property need to be added to the Alarm Control
Properties section after the ShowGrid property. The following descriptive
content needs to be added: The ShowGroupByHeader property is a read-write Boolean property to show or hide the column grouping label at the top of the run-time Alarm Control in the historical mode. You can set the ShowGroupByHeader property to true to show the label "Drag a column header here to group by that column". |
3 | Guide
to ArchestrA Alarm Control, aaAlarmClientControl.pdf p.27 ArchestrA Alarm Control Help, aaAlarmClientControl.chm, "Showing Current Alarms or Recent Alarms and Events" |
For Alarm Controls
hosted by Automation Object templates or instances, you can specify one of
the following alarm queries:
For more information on absolute alarm queries, see Alarm Queries in the InTouch HMI Alarms and Events Guide. |
For Alarm Controls
hosted by Automation Object templates or instances, you can specify one of
the following alarm queries:
For more information on alarm queries, see Alarm Queries. |
4 | Creating and Managing
ArchestrA Graphics User's Guide (aaGraphics.pdf), "String Substitutions and Language Switching" section, page 426 Application Server Help (IDE.chm), "String Substitutions and Language Switching" topic |
n/a | Add the following text after the first
paragraph: If you perform a first-time string substitution on an embedded symbol in the primary language, that substitution is shown in the secondary languages. You can then perform a substitution in the secondary language to create a string substitution specific to the secondary language. If you perform a first-time string substitution on an embedded symbol in a secondary language, the substitution is also applied to the primary language, because the translated string that previously existed for the primary language is no longer valid. Because the primary language value is changed in the symbol, this string applies to all secondary languages configured. You can then perform a second substitution in the primary language, which will apply to all secondary languages except the ones that have had a specific substitution set. If you perform a string substitution in a secondary language with an existing string substitution in the primary language, the new substitution is applied to the secondary language only. |
Saving the Date Timestamp as Historical Data
If slow updates for real-time data values are received from an I/O source and an intermittent network disconnect occurs, the timestamp of the first data value of a historized attribute uses the AppEngine's timestamp instead of the source's timestamp. In the following example, in row number 4, the value "30" is sent again to the historian, but the timestamp is the AppEngine timestamp and not the actual timestamp of "2008-11-24 18:50:41.061" when the value of 30 was generated from the I/O source.DateTime | TagName | Value | Quality | QualityDetail | OPCQuality |
2008-11-24 18:48:30.081 | Realtime_Client.ival | 20 | 133 | 44 | 192 |
2008-11-24 18:50:41.061 | Realtime_Client.ival | 30 | 0 | 192 | 192 |
2008-11-24 18:51:38.666 | Realtime_Client.ival | NULL | 1 | 24 | 0 |
2008-11-24 18:52:06.670 | Realtime_Client.ival | 30 | 0 | 192 | 192 --> Row number 4 |
2008-11-24 18:53:22.988 | Realtime_Client.ival | 40 | 0 | 192 | 192 |
DateTime | TagName | Value | Quality | QualityDetail | OPCQuality |
2008-11-24 18:48:30.081 | Latedata_Client.ival | 20 | 133 | 44 | 192 |
2008-11-24 18:50:53.624 | Latedata_Client.ival | 30 | 0 | 192 | 192 |
2008-11-24 18:50:53.625 | Latedata_Client.ival | NULL | 1 | 24 | 0 |
2008-11-24 18:50:53.630 | Latedata_Client.ival | 30 | 0 | 704 | 192 --> Row number 4. |
2008-11-24 18:53:26.863 | Latedata_Client.ival | 40 | 0 | 192 | 192 |
Application Server Documentation
The Application Server product library consists of a set of Portable Document Files (PDF) located in the UserDocs\English folder of the Application Server installation CD. You need Adobe Reader installed on your computer to view Application Server documentation. You can download the latest version of Adobe Reader from the Adobe Corporation web site: http://www.adobe.com/products/acrobat/readstep2.html After installing Adobe Reader, double-click on a PDF file with your pointing device to view the book with Adobe Reader. You can also open a book with the Adobe Reader Open command from the File menu. Application Server installation instructions are located in the root folder of the Application Server installation CD as an online help file. You can view these instructions by clicking the Installation Guide button in the Application Server installation program. Product documentation is also available with Application Server online help.Documentation Set
The Application Server documentation set includes the following guides:- Wonderware Application Server User's Guide. Explains configuring and deploying Application Server applications.
- Creating and Managing ArchestrA Graphics User's Guide . Explains how you create and manage graphical symbols using the ArchestrA Symbol Editor within the Integrated Development Environment (IDE).
- Application Server Scripting Guide. Reference for the scripting language in Application Server.
- Object Viewer User's Guide. Explains how to acquire run-time data using the Object Viewer.
- Guide to the ArchestrA Alarm Control. Explains how to configure the alarm control (client) to show current and historical alarms and events in a grid.
- Guide to the ArchestrA Trend Client. Explains how to configure a chart to trend real-time data values.
- Platform Manager User's Guide. Explains how to start and stop system components.
- Galaxy Database Manager User's Guide. Explains how to backup and restore the Galaxy database.
- Log Viewer User's Guide. Explains how to use the Log Viewer utility to determine system diagnostics.
- Log Flag Editor Utility Guide. Explains how to turn on and off certain diagnostics logging messages.
- Wonderware FactorySuite License Utility Guide. Explains how to use the License Utility to manage the license required for the running application.
- Wonderware ArchestrA Protocol Guide. Explains background information on the main protocols used between components of Wonderware products.
- Application Server Installation Guide. Explains information about installing the product.
- InTouch HMI and ArchestrA Integration
Guide. Explains how you can use the ArchestrA Integrated Development
Environment (IDE) to manage InTouch applications so that you can use symbols
you create in the ArchestrA Symbol Editor. This guide is available on the
InTouch HMI installation CD.
Searching Application Server Books with Adobe Reader
The Application Server version 3.1 books are delivered as an Adobe PDF package, which provides a master index of all books. Using Adobe Reader, you can simultaneously search for a specific topic across all books that belong to the Application Server product library.To search for information across all Application Server books simultaneously
- Open Adobe Reader.
- Press CTRL+SHIFT+F or select Search from the Edit menu. The Search dialog box appears.
- Type the word or phrase that you want to search for in the Application Server books.
- In the Where would you like to search area, select the option to search all PDF books.
- If necessary, locate the Application Server version 3.1 PDF package located on your Wonderware CD or on a network folder containing copies of the Application Server PDF book files. After product installation, these files can be found at: <drive letter>:\Program Files\ArchestrA\Framework\Docs.
- Click Search. Adobe Reader lists the Application Server books that contain a match for your search criteria.
- Click on the links to open the Application Server book to the topic containing the information that meets your search criteria.
© 2009 Invensys Systems, Inc. All Rights Reserved.