InTouch Machine Edition 2014 p07 (7.1 SP3 Patch 07)
Release Notes For InTouch Machine Edition
InTouch Machine Editionv7.1 + Service Pack 3 + Patch 7 (Wednesday, October 07, 2015)
ID | Type | Description |
2363 | Issue | Resolved issues with VBScript on WinCE devices when using certain FileSystem VB functions |
3066 | Issue | Resolved an issue where users would be able to select Retentive Parameters for tag configuration on Embedded target applications, even though Retentive Parameters is not supported for Embedded applications. |
3476 | Issue | Resolved issue with the X-Ref feature not finding tags configured on the "Execution" field of the Script worksheets |
4042 | Issue | Resolved an issue where the Viewer module generated an error when trying to close a screen that called a MsgBox function in the OnClose screen script. |
8707 | Issue | Enhanced Mobile Access interface to support Tag Integration tags |
9568 | Issue | Resolved issue with the Alarm Rate feature not working properly. |
9749 | Issue | Resolved issue where two instances of the runtime were executed in parallel when the first was running as a Windows service and the user also ran the normal runtime without Administrator privileges. |
10223 | Issue | Resolved issue with the Text Object cuting some pixels on the Left of its content while being displayed on the Viewer Module |
10236 | Issue | Resolved an issue where pasting a system symbol on a application more than once would ask the user to overwrite the application's symbol even without changing either symbol, also made sure that application symbols that erroneously link to system symbols are copied over to the application's linked symbol folder. |
10305 | Issue | Resolved an issue with the wrong Object ID being displayed on the Output window after running the Verify command when an animation with an invalid tag was applied to an existing linked symbol |
10346 | Issue | Resolved issue with the "Period" dialog of Trend Object not properly setting the time during the Daylight Saving period |
10460 | Issue | Modified the Database connectivity feature to resolve issue with some Operating System Regional Settings |
10469 | Issue | Resolved issues with the Trend Control object drawing addition lines when the period displayed was within the Daylight Saving |
10555 | Issue | Resolved issue with the Alarm Task not properly storing the historical information when configured to use Database, and not using it in UTC mode |
10562 | Issue | Resolved issue with the Event Logger not working properly when the database was configured for Local Time + Bias |
10591 | Issue | Resolved issues with the OPC XML-DA not finding some specific servers. |
10663 | Issue | Resolved issue with the Output Window showing an incorrect message when saving a screen that has objects with the VBScript commands containing Array Tags with VBScript variables as index |
10704 | Issue | Resolved issue with Tag Integration for RSLogix5000 related to Arrays and UDTs having arrays as members |
10757 | Issue | Resolved issue with the "Replace Tag" command on a screen not properly replacing tags that were being used on Command animation if the Command animation was applied to a Linked Symbol |
10760 | Issue | Resolved issue where the "Min" and "Max" texts fields on the Virtual Keypad were not being translated using the Translation Tool |
10783 | Issue | Resolved issue with the Print Orientation, in which after printing a screen using the PrintWindow() function in Landscape orientation, the PrintWindow() would no longer print in Portrait orientation. |
10808 | Issue | Resolved issue with the Command Property not properly executing the commands configured on the "OnUp" tab using shortcut keys |
10845 | Issue | Resolved issue with the Text Box object not properly updating its contents when the "Input Enabled" option was not checked. |
10847 | Issue | Resolved issue with the FileCopy() built-in function not creating the target file with its correct name when the optTimeout parameter was being used |
10878 | Issue | Resolved issue with the caption on buttons and rectangles when they were grayed out |
11113 | Issue | Resolved issue with Tag Integration for RSLogix5000 related to Arrays and UDTs having arrays as members |
11142 | Issue | Resolved issue with the Commands to Close() Screens no longer working on Web Thin Clients |
11143 | Issue | Resolved issue with the ShowInplaceInput function not working if you have the Virtual Keyboard enabled |
11149 | Issue | Modified the resource handler of the PDF printer to avoid race conditions |
11166 | Issue | Resolved an issue where configuring array strings on the OPC-UA sheet and not using indexes to access specific elements of the array would cause the OPC-UA array to not be read properly. |
11184 | Issue | Modified the FTPStatus() function to return the value "1" at least once when the FTPPut() is executed successfully |
11212 | Issue | Resolved issue the Object Finder that the Index shows one extra position when using arrays in the RSLogix 5000 tag integration. |
11614 | Issue | Resolved issue with the Date when automatically sending alarms via email, depending on the time zone. |
11653 | Issue | Resolved issue with Dialog and Pop-up screens being closed automatically when there commands calling 2 message boxes in a row |
11665 | Issue | Resolved issue with the FileWriteFields() function not working properly with arrays when trying to access the last array position |
10736 | Change Request | Modified the OPC UA Log message when writing and reading logical TRUE and FALSE for Boolean Tags / OPC items. |
9869 | Change Request | Created an option to enable/disable the behavior of the “Ok” key from the Alphanumeric Virtual Keyboard (Project > Settings > Viewer > Virtual Keyboard > Enable multi-line text input). |
InTouch Machine Editionv7.1 + Service Pack 3 + Patch 6 (Friday, June 26, 2015)
ID | Type | Description |
1329 | Issue | Modified the Windows CE runtime to properly handle touch screen events and reset the NoInputTime function |
1720 | Issue | Modified the X-Ref to search for tags stored in the Event Logger |
2854 | Issue | Resolved issue with the Alarm Control object not properly sorting its contents by the "Messages" column |
3079 | Issue | Resolved issue with the translation of the word "Duration" on the Trend Control object returning to the original language when switching between screens |
3386 | Issue | Resolved issue with the recipes not reading the XML files that did not have line break between the XML tags |
3427 | Issue | Resolved issue with Alarm not being acknowledged on the Alarm Control object by double-clicking on one of the Custom Field Columns |
5207 | Issue | Resolved issue with the Column width for Alarm Object Custom Fields |
5302 | Issue | Resolved issue with Grid object having Data Source as Class Tags not working as it used to in previous versions |
6772 | Issue | Resolved issue with a combination of modifier keys, such as Ctrl, Alt, Shift, and another keys, not executing the commands configured on the OnUp scripts when the modifier keys were being released first |
6838 | Issue | Resolved issue with Tag Integration not being able to properly synchronize class members to Structure and UDTs that were modified. |
7357 | Issue | Resolved issue with the Trend Control object, that when clicking on the "Cancel Zoom" command, the pen line on the Trend chart was sometimes being plotted in random places |
7488 | Issue | Modified the PrintWindow() function to no longer allow the user to try to print on the StudioPDF printer, which would cause the system to not work properly |
7495 | Issue | Modified how linked symbols are saved in a project: when you paste a linked symbol into a screen, the symbol file will be copied to the project's Symbol folder if it is not already there. If that same symbol is already there, identical, and with the same name, the newly pasted symbol will link to the same file, otherwise, the user will be prompted if the new symbol should replace the existing one or not |
8423 | Issue | Resolved issues related to the Mobile Access feature when there were multiple simultaneous connections and disconnections. |
8487 | Issue | Resolved issue with the Secure Viewer and Web Thin Client taking twice the time configured to switch stations to completely connect to the second server when having server tags on the screen that is open |
8491 | Issue | Resolved issue with the Tag Integration for Rockwell PLC5/SLC500 using too much memory and processor |
8588 | Issue | Fixed problems to run the Fluke DAQ application. |
8676 | Issue | Linked symbols that contain linked pictures will be properly compared when pasted to an application avoiding unnecessary overwrite operations. |
8697 | Issue | Resolved leak of memory issue with the OPC Server module that was happening with some specific calls from OPC Clients |
8777 | Issue | Resolved issue when opening a screen with mnemonics and class tags, on the Min and Max of the dynamic properties, such as bargraph, text, text box, position, rotate, size |
8786 | Issue | Resolved issue with the Grid Control not working properly when switching the Date format using the SetDateFormat function on the Viewer module |
8799 | Issue | Resolved issue with sending alarms via Email, having more Custom Fields enabled than what was actually configured on the Alarm Worksheet, that would cause the system to become unstable |
8842 | Issue | Resolved issue with the Trend Annotation not working properly after executing the SetDateFormat() function on the Viewer Module |
8848 | Issue | Modified the Trend Control object to update the Date Format on the X axis after the SetDateFormat() is executed |
8865 | Issue | Resolved issue with the E-sign not working properly on Secure Viewer after disconnecting from the server and reconnecting to it. |
8874 | Issue | Resolved issue with the ShowInplaceInput() function ignoring the following parameters: numStartXPos, numStartYPos, optNumEnablePasswordMode. |
8877 | Issue | Resolved issue with the "Insert Copied Cells" command not working properly when used in the worksheet's blank cells replacing existing rows. |
8878 | Issue | Resolved issue with the Text object with the Dynamic Position property, when the SetLanguage() function was being called, it would cause the translated text object to return to its original position until the Position value change or the screen is reopened |
8885 | Issue | Optimized the initialization of the Trend Worksheets when configured to communicate with the Wonderware Historian. Before this change, the Studio Database Gateway (StADOSvr.exe) would take too long to initialize and would cause a timeout with the runtime. |
8890 | Issue | Modified the Database Interface Trace messages on the store and forward capability to display local time instead of UTC. |
8891 | Issue | Modified the OPC Client modules (both the OPC DA 2.05 and the OPC XML/DA modules) to update the studio tag properties (TimeStamp and/or Quality) when receiving a message from the OPC Server, even if the tag value does not change. |
8900 | Issue | Resolved issue with the Security System causing the user to lose its privileges when switching screens, in very specific situations, when running in LDAP mode |
9012 | Issue | Resolved issue with the "Verify" command displaying message related to the Security System, even though the Security System was disabled, in some specific projects |
9129 | Issue | Resolved issue with the Grid object not allowing the user to properly scroll through the rows once one of them was selected |
9153 | Issue | Resolved issue with the OPC Server not runing as a Service if you configure the service to run with a user different than the one that is current logged on |
9158 | Issue | Resolved issue with "Remove unused tags" functionality trying to remove class array tags that are actually being used in the projects when their indexes are VBScript variables |
9191 | Issue | Resolved issue with the Trend Control having some points disappearing when it was in Run Mode and displayed on Web Thin Clients |
9219 | Issue | Modified the EmbeddedView to run on devices where the image does not contain the basic c++ libraries. |
9230 | Issue | Resolved issue with the Viewer displaying the background bitmap even after the user disabled it |
9240 | Issue | Resolved issue with the TCP/IP Server task not being automatically enabled when saving screens as HTML for the first time, like it used to do |
9315 | Issue | Resolved issue with the Trend Control not showing data properly when the database was configured to use Local Time + Time Difference |
9328 | Issue | Resolved issue with the Development Environment turning very slow after some time due to temporary files being created |
9332 | Issue | Resolved issue with the Security System not working properly in Distributed Mode when there were several Distributed Remote clients connected to that same server |
9381 | Issue | Modified the Mobile Access Script Engine to properly handle cases where with a MsgBox call containing spaces before the parenthesis. Before this modification, screens containing expressions such as 'MsgBox ("Test" )' would fail to load. |
9456 | Issue | Resolved issue on Windows Embedded (both Compact and Standard) with the Trend task having errors when trying to store to a database tags with bad quality |
9518 | Issue | Resolved issue with the Scan configuration not working properly when the option "Screen" was selected on the Driver, OPC DA 2.05, OPC UA Client and OPC XML-DA runtime tasks |
9565 | Issue | Resolved issue with the Filecopy function not working properly when the destination parameter is only the path, without the file name, and the user does not configure the optTimeout parameter |
9570 | Issue | Resolved issue with the Tab Order on a screen being overwritten if an object had a dynamic property associated to it |
9574 | Issue | Implemented a new feature to save the Security System information every 5 minutes, to avoid that changes made during the runtime to be lost in case of an unexpectedly system failure. |
9768 | Issue | Resolved issue with class member replace function not replacing the tag members properly in projects with arrays in scripts that were using VBScript variables as indexes. |
9770 | Issue | Fixed the Wonderware Historian to properly parse strings in curly brackets for the Trend Task when using database. |
9819 | Issue | Resolved issue with files being removed from the project when other applications, such as back up and anti-viruses, were locking these files at the same time that we were trying to write to them |
9852 | Issue | Modified the Trend Control object to allow the user to use the Window Zoom to include the scale limits on the selection |
9853 | Issue | Modified the Popup Input window to show the same value as the Text Object that called it when it is open |
9854 | Issue | Fixed the grid control to properly print or send to PDF files when using the multiline option. |
9873 | Issue | Resolved issue with the FindFile function no longer working properly when using the optTimeout parameter |
9877 | Issue | The TagsDBGetAlarm function can now handle the maximum message alarm size. |
9887 | Issue | Resolved errors when trying to open corrupted screen files |
9982 | Issue | Resolve Tabulation issue with the Text Box control on Web Thin Clients |
9990 | Issue | Resolved issue with Multi-touch functionality becoming unstable in certain specific situations |
10014 | Issue | Resolved an issue with the Tag Integration for RSLogix 5000 where it did not properly import some array tags. |
10017 | Issue | Resolved issue with the "Verify" command causing the system to be unstable when there were corrupted screen files on the project. |
10217 | Issue | Resolved issues with the Trend Control not properly drawing the lines and having issues when scrolling through the period of time during the Daylight Saving change |
7372 | Change Request | Created a new log message that is displayed on the Output Window and LogWin when the Auto LogOff is executed |
8335 | Change Request | Modified the Mobile Access Tabular to be registered as the Launching User |
8465 | Change Request | Changed the Security System AES initialization to prevent corrupting the Security System files |
8614 | Change Request | Enhanced the Tag Integration for Schneider Unity Modbus to support %M addresses and for tags declared as DWORD. |
9114 | Change Request | Modified E-Signature window to do not grayout the User Name field by default when the timeout value has not been elapsed |
9984 | Change Request | Modified Security System in LDAP mode to use a different ping implementation |
9993 | Change Request | Enhanced the Tag Integration with TwinCAT to support online retrieval of the variables configured in a runtime PLC instance. |
7820 | Requirement | Improved the Tag Integration for the TwinCAT provider to support TMC and TMI files. |
InTouch Machine Editionv7.1 + Service Pack 3 + Patch 5 (Friday, March 20, 2015)
ID | Type | Description |
5671 | Issue | Modified OPC UA Client to display an error message in the log when communicating with unsupported items |
5987 | Issue | When deleting a screen using the Project Explorer treeview, now all the files related to that screen that were saved on the Project’s Web folder, such as the html, scc and ssma files are also deleted |
6268 | Issue | Resolved issue with the Trend Control object not working properly when using the Local Time + Time Difference option to save the data on the Trend worksheet |
6938 | Issue | Modified the Mobile Access to prevent memory leaks when connecting and disconnecting clients. A small leak would eventually make the Mobile Access stop responding. In order to restore the user would have to reset the IIS application pool. |
7362 | Issue | Resolved issue where the Visibility property was not working properly with ActiveX objects |
7511 | Issue | Resolved issue with the Hardkey license not working properly when some other software packages such as Rockwell Studio5000 and Codesys v3.5 were installed on the same computer |
7584 | Issue | Resolved issue with the Tag Integration for RSLogix not working properly when some L5K files contained several levels of nested UDT |
7725 | Issue | Resolved issue with the Screen Scripts Screen_OnOpen and Screen_OnClose procedures, that were sometimes being executed incorrectly on a startup screen when it was being reloaded. |
7882 | Issue | Resolved issue with the Trend Control not properly handling the pens and duration after zoom was being used, and the user closed and reopened the screen that had that object, causing invalid values to be loaded on the limits and duration |
7883 | Issue | Resolved issue with the Trend Control object not properly drawing the pens when scrolling back and forth, when the Data Source is MS Access with a large amount of data saved |
7884 | Issue | Resolved issue where the Virtual Keyboard was being opened in unusable places in the screen |
7909 | Issue | Fixed a problem in Mobile Access where modifying a tag continuously (i.e.: Screen OnWhile logic) on the client would make the client stop receiving updates on the server. |
7911 | Issue | Resolved issue with the Remote LogWin causing errors in certain projects running on Windows Embedded Standard 7 |
7913 | Issue | Resolved issue with RSLogix5000 Tag Integration when the L5K file had strings created with a certain number of characters as value causing a line feed |
7956 | Issue | Resolved issue with deleting rows from worksheets after sorting by the Tag Name column |
8023 | Issue | Resolved issue with the custom Watch Dog tag for the Secure Viewer Thin Client not working properly in redundant mode |
8031 | Issue | Resolved issue with the HST2TXT function causing errors when the date format in the Thin Clients and the Server are different. |
8043 | Issue | Modified the OPC UA Client to properly handle invalid configuration files. |
8046 | Issue | Resolved issue where the “Test Screen” feature was enabling the background color on Text objects having the Text Data Link property and the Input enabled |
8125 | Issue | Resolved issue with the built-in IF() function not working properly when it had mnemonics on the parameters, and when running specifically on WinCE devices, ARMV4I platform |
8132 | Issue | Modified the EmbeddedView run-time to remove the requirement of having the C++ libraries in the embedded device image |
8198 | Issue | Resolved an issue that was happening when we tried to close certain screens that were already invalid |
8216 | Issue | Resolved issue with EmbeddedView OPC DA Client not properly handling TimeStamp values received from the OPC Servers |
8242 | Issue | Resolved issue with the Remote Agent (CEServer.exe) not recognizing Hardkeys on Windows Embedded Compact (CE) and Windows Embedded devices with a brand new installation |
8290 | Issue | Resolved issue with the StrFromTime() function not working as described in the documentation. |
8331 | Issue | Modified the Mobile Access to properly evaluate the security level at the Main (root) node. |
8441 | Issue | Resolved issue with the Class members editor that was allowing the user to create class members with invalid characters |
8502 | Issue | Modified the OPC UA Client to properly check for good qualities. When receiving good quality different from OpcUa_Good the OPC UA Client was reporting them as bad quality.. |
8507 | Issue | Resolved issue with the FileCopy() function returning an error if source file has the read-only attribute set, even with the file being properly copied, when if you configure any value on the last parameter optNumTimeOut |
8559 | Issue | The Viewer does not leak memory when switching screens with tags inside rectangles. |
8575 | Issue | Modified Mobile Access to support access to the server through a router without having to configure the Web.Config file |
8587 | Issue | Resolved memory allocation issue with the Text Box Control object |
8589 | Issue | Resolved issue in the StudioToolkitNET with the UNTranslateEX function |
8619 | Issue | Tag Integration: Resolved issue to enforce that all tags are properly mapped (between Studio and TwinCAT), even after modifying the configuration of structures (classes) in the TwinCAT program (e.g.: adding or removing members) |
8649 | Issue | Resolved issue with the event logger feature not logging the first log on action on a Web Thin Client |
9219 | Issue | Modified the EmbeddedView to run on devices where the image does not contain the basic c++ libraries. |
8111 | Change Request | Enhanced the Register module to make the selected network card persistent when using Softkey and opening the “Settings” window. |
8325 | Change Request | Implemented a new capability to dynamically change the Screen Background Image using {Tag} on the “Shared image” field of the Screen Attributes window |
8332 | Change Request | Modified the way that passwords are saved on screen files when protecting them with passwords. |
8607 | Change Request | Created new configuration in the app file to deny blank passwords when using the Security System in LDAP mode |
8731 | Change Request | Increased the length of the string that can be entered on the LDAP Query Filter configuration |
9028 | Change Request | The following entry in the "ApplicationName.APP" file has been created to disable a background thread for the LDAP connection, which may result in inconsistent results from certain LDAP Servers: Section [Options], parameter "EnableThreadLDAP=0" |
InTouch Machine Editionv7.1 + Service Pack 3 + Patch 4 (Thursday, December 18, 2014)
ID | Type | Description |
4944 | Change Request | Implemented new Data protection feature to encrypt sensitive information |
5188 | Change Request | Improved Trend Control to allow 'Cancel Window Zoom' if the user stops and re-runs during the runtime. |
6612 | Change Request | Modified the Translation feature to no longer automatically import some of the Data from the Database configurations on screen control objects connected to Databases, such as Grid Control, Trend Control and Combo Box |
7239 | Change Request | Modified the GetHardkeySN() function to properly return the updated value when removing or replacing the Hardkey after starting the application |
4945 | Requirement | Modified the way the encrypted data is exchanged |
7353 | Requirement | Enabled the ShowMessageBox function to work also when called by a Background Task |
5954 | Issue | Resolved issue with a a buffer overflow being generated when reading a corrupted screen |
6395 | Issue | Resolved issue with some parameters of the Trend Control object not working properly when using the Open() function and mnemonics |
6493 | Issue | Resolved issue with using a String Tag on the Trend Control Duration field and zooming in, out and cancelling zoom not properly rounding the values |
6506 | Issue | Resolved issue with GetAppPath() function returning a value with 2 backslashes at the end after the project has been downloaded to a Window PC target system |
6613 | Issue | Resolved issue when using the Portuguese MUI and not being possible to see the correct number of tags on the text field on the lower right corner of the Development Environment that shows the tag count |
6652 | Issue | Modified the Mobile Access to support iOS8 |
6655 | Issue | Resolved issue with PanelBuilder Import wizard creating an invalid scheduler worksheet when importing projects without a tag assigned to the screen number |
6656 | Issue | Modified the mobile access to support screen name with space when specifying the screen name in the query string (e.g.: http://localhost/ma?screen=Screen%20With%20Space) |
6773 | Issue | Enhanced the login page to display more precise information when the logon fails. |
6803 | Issue | Fixed problem with functions GetTagValue and SetTagValue for Mobile Access. The functions were not working properly if the TimeStamp field was part of the tag name specified e.g.: GetTagValue( Tag->TimeStamp ). |
6808 | Issue | Resolved issue with the Collaboration Tool not properly handling the Email information saved on the Alarm worksheets |
6977 | Issue | Resolved issue with the Trend Control object where the Cursor Output Value, in certain situations, was displaying a wrong value when the screen having this object was first open |
7038 | Issue | Resolved issue with the print orientation not working properly when printing using the trigger on the Grid Control object |
7179 | Issue | Fixed system error on Mobile Access when loading several clients simultaneously. |
7210 | Issue | Modified the dialogs of certain objects on the Web Thin Client to no longer have the “Close” system menu, no longer be able to drag them and do not allow right clicking on them |
7221 | Issue | Resolved issue with the Mobile Access that, on certain situations, when saving screens, the font object was being set to an invalid value. |
7238 | Issue | Resolved issue with the Date and Time functions not returning the correct values depending on the Daylight Saving status and parameters |
7293 | Issue | Resolved issue with Secure Viewer connected to redundant servers having issues when switching servers |
7374 | Issue | Modified the Mobile Access to display '????' in the tag value when an invalid tag or an invalid array index is specified. Prior to this change Mobile Access would display System.Object |
7380 | Issue | Fixed an issue with Mobile Access VBScript parser where function calls receiving array tag(s) as parameter(s) would not work as expected. |
7430 | Issue | Resolved issue with the Auto-LogOff feature not working properly when the Security System is configured to LDAP mode |
7440 | Issue | Resolved issue with the SetLanguage function causing errors on the TCP/IP Server task when called simultaneously from different Thin Clients |
7458 | Issue | Resolved issue with the modifier keys causing commands configured on the “On Up” action of the Command animation to be executed |
7465 | Issue | Resolved issue with Remote Management not being able to connect to PocketPC in ActiveSync mode |
7504 | Issue | Resolved issue with the Security System, when switching between LDAP and Local modes, and restarting the software, causing the LDAP settings not to be retained |
7522 | Issue | Resolved issue errors that were happening when we tried to close certain screens that were already invalid |
7646 | Issue | Resolved issue with the SNMP agent not working properly |
7747 | Issue | Resolved issue with Secure Viewer not displaying Linked Pictures addressed with absolute paths |
InTouch Machine Editionv7.1 + Service Pack 3 + Patch 3 + Hotfix 2 (Wednesday, November 12, 2014)
ID | Type | Description |
7458 | Issue | Resolved issue with the command animation, that when pressing and releasing one of the modifier keys (i.e. Ctrl, Alt, Shift), during the Runtime, could cause the commands configured on the “On Up” action to be executed even if they were not associated to keyboard shortcuts. |
InTouch Machine Editionv7.1 + Service Pack 3 + Patch 3 (Tuesday, October 28, 2014)
ID | Type | Description |
3696 | Requirement | Implemented Tag Integration interface for the AutomationDirect DoMore PLC Family. |
5394 | Requirement | Enhanced the Mobile Access solution to support the Security System Auto LogOff feature |
5859 | Requirement | Added support for General alarm fields for the TagsDBSetAlarm and TagsDBGetAlarm functions |
5998 | Requirement | Implemented capability to customize the Viewer icon on the Task Bar. |
6061 | Requirement | Created a new built-in function, GetLastESignUser(), that returns the name of the user authenticated to execute a screen Command (animation) with E-signature |
6262 | Requirement | COSYS Tag Integration: added ARTI3 support |
4713 | Issue | Resolved issue with the translation feature not working on the Combo Box object when using data source as Database |
4726 | Issue | Changed the way Development Environment handles the Fill Effects for rectangles when the system is targeted for an Embedded runtime |
5032 | Issue | Resolved issue with the Import Wizard Tags Filter Dialog not working for any language other than English |
5166 | Issue | Resolved issue with Remote Management, when connectign to a EmbeddedView system, if your target folder is not a Subfolder of the Remote Agent (CEServer), the selected target folder is not kept |
5299 | Issue | Resolved issue with the Text Data Link dynamic property not being updated when the Screen Attribute parameter Hide screen instead of closing it was checked |
5330 | Issue | Resolved an issue where an incorrect message was displayed when the project developer tried to insert the same System Symbol more than once. |
5376 | Issue | Resolved issue with the Ctrl+F Find functionality ignoring the last row on any worksheet on the development environment, such as Driver, Scheduler, Math, and so forth |
5616 | Issue | Modified the Protection Manager to allow you to select a MAC address when you change your softkey license. This is necessary because the license's site code is based on the computer's MAC address, and the computer may have more than one MAC address if it is connected to a VPN or otherwise using a virtual NIC at the time that you change your license. |
5652 | Issue | Fixed a problem with the OPC DA 2.05 worksheet where the Div column would display a wrong label. |
5666 | Issue | Resolved issue with the popup input for text object not being properly displayed when more than one monitor was being used |
5804 | Issue | Resolved issue with Remote Management experiencing timeout problems when downloading projects to remote computers when the Remote Agent is configured with users and passwords on its Security System |
5871 | Issue | Resolved issue with the Trend Control object when enabling the Advanced-> Auto Save option, it would cause some tags configured in the fields to not work properly |
5884 | Issue | Resolved an issue where the built-in function TagsDBAddTag would not accept new tag names beginning with the "@" character. |
5910 | Issue | Modified the OPC XML/DA to properly set the quality of the tags to BAD when the client fails to connect to the server. |
5939 | Issue | Resolved issue with the Output Window and LogWin module no longer showing Database messages that would include important information such as wrong table or column names when using the Grid Control |
5946 | Issue | Resolved issue with the Trend Control object not accepting mnemonics on the Axes->Duration field |
5976 | Issue | Resolved issue where opening the “Config” window of the Command property Object Properties, and clicking on the “Cancel” button, would delete the VBScript configured on it |
5978 | Issue | Resolved issue with Alarm Control not being able to properly use the Filter Expression when it had Custom fields containing lower case characters or when the last Custom field was being used |
5987 | Issue | When deleting a screen using the Project Explorer treeview, now all the files related to that screen that were saved on the Project’s Web folder, such as the html, scc and ssma files are also deleted |
5997 | Issue | Resolved issue with the Report task not working properly when some Asian characters were used |
5999 | Issue | Resolved issue with the capability to save the alarm state whem the alarm is generated by the Driver and/or OPC, the alarm selected tag showed a string in the format #:#:#:# instead of the tag name. |
6009 | Issue | Resolved issue with the tag not having its value properly displayed on some specific screen objects with animations. |
6059 | Issue | Modified the built-in RunGlobalProcedureOnTrigger() function to work also when called from a Secure Viewer Thin Client |
6060 | Issue | Resolved issue with the Security System when using Tags in the “Password Aging” and/or in the “E-signature timeout” fields from “Security System > Groups > [GroupName] > Advanced” dialog being reset to their “lowest value after running the application” when executing GetUserFullName() |
6095 | Issue | Resolved issue with the Remote Management tool not allowing the user to select a non-empty folder as your target application when browsing for a target folder in the development environment |
6107 | Issue | Modified the Database Functions to display an error message on the log when the maximum number of connections with the database is exceeded. |
6140 | Issue | Resolved issue with the Virtual Keyboard not being properly placed when the user had more than one monitor |
6167 | Issue | Resolved issue where it was not possible to configure mnemonics on the Trend Control > Axes > Duration field, even though we could configure a tag on the same field |
6185 | Issue | Resolved issue with using the Print button on the Trend Control object was not printing values on the SPC columns when they are configured to be displayed (Min, Max, Avg, etc...) |
6314 | Issue | Resolved issue with key combinations on the Command animation not working on the OnUp scripts when one of the keys was being released first |
6325 | Issue | Modified the Mobile Access scripting engine to properly handle line breaks and user functions with suffix MsgBox. |
6432 | Issue | Resolved issue with the X-Ref tool wrongly showing that the tags would be present in certain documents where they were not |
6453 | Issue | Resolved issue with the Trend Control using Data Source as Text and the X-Axis containing Date/Time information |
6522 | Issue | Resolved issue with the Mobile Access interface where the Mobile Access Client would stop receiving tag changes from the server. |
6582 | Issue | Modified the Mobile Access to prevent fatal error when closing a screen with Combo Box before the Combo Box can load its data. |
6792 | Issue | Resolved issue with security system in distributed mode causing the TCP/IP server task to create unnecessary connections. |
7458 | Issue | Resolved issue with the command animation, that when pressing and releasing one of the modifier keys (i.e. Ctrl, Alt, Shift), during the Runtime, could cause the commands configured on the “On Up” action to be executed even if they were not associated to keyboard shortcuts. |
InTouch Machine Editionv7.1 + Service Pack 3 + Patch 2 (Friday, August 08, 2014)
ID | Type | Description |
2872 | Requirement | Modified the Trend task to make it easier to troubleshoot when historical data are not saved correctly. |
3316 | Change Request | Modified the message that is displayed when the project developer clicks "Trust server certificate" in the security settings for an OPC UA connection (OPC UA > Connections > Server Configuration > Security), in order to warn them when the certificate is self-signed. |
4994 | Change Request | Implemented the new built-in functions TranslationLookupLoad, TranslationLookupGet, and TranslationLookupClose, which allow the project developer to create lookup maps between different languages. For more information, see the documentation. |
4995 | Change Request | Improved the ADO.NET database gateway (StADOSvr) to make it possible to specify a locale (i.e., language and country) for database queries, rather than use the locale that is specified in the host's system settings. |
5685 | Change Request | Modified the built-in function CheckESign to take a security access level as an optional parameter. Previously, the function would validate against level 0, and level 0 is still the default, but this parameter allows the project developer to specify any level. |
3989 | Issue | Resolved an issue with Linked Symbols that are configured to use Class tags imported via tag integration. |
4025 | Issue | Resolved an issue with the built-in function FileWrite, where it did not properly handle the Visual Basic CRLF character (vbCrLf). |
4372 | Issue | Modified the built-in function SetViewerPos to be able to take negative values as parameters. This is to make it easier to manage the Viewer on multiple monitors. |
4461 | Issue | Resolved an issue with the Smart Message object not displaying the last configured message. |
4545 | Issue | Modified the interface between the development station and the target station in order to avoid errors when using the "Get From Target" command (Remote Management > Import) to import projects from the target station. |
4903 | Issue | Resolved issues with Runtime for Windows Embedded Compact not properly interacting with SQL CE 3.5. |
5059 | Issue | Resolved an issue with the project security system where, if a project had been running for extended period (i.e., more than one week), creating a new user would generate errors. |
5064 | Issue | Resolved an issue where the OPC UA Client task would sometimes crash if it attempted a read/write operation while it was disconnected from the OPC UA server. |
5092 | Issue | Modified the ADO.NET database gateway (StADOSvr) to work even if Microsoft .NET Framework 4 is not installed on the computer that hosts the gateway. .NET Framework 4 became a requirement when support for Wonderware Historian was implemented in a previous release (see item 3423). This modification ensures that the gateway will continue to work for most database connections, but if you plan to connect to a Historian database, .NET Framework 4 is still required. For more information, see the documentation. |
5099 | Issue | Resolved an issue with the EmbeddedView runtime where it did not show the window menus (File, Security, Tools) even if it was configured to do so (Project Settings > Viewer). |
5185 | Issue | Resolved an issue where the "Test Screen" command would change the background color of Text objects that have the Text Data Link animation applied to them. (To access the "Test screen" command, right-click in the project screen editor.) See also item 5186. |
5186 | Issue | Resolved an issue where the "Test Screen" command would change the size of some screen objects that have the Position/Visibility animation applied to them. (To access the "Test screen" command, right-click in the project screen editor.) See also item 5185. |
5208 | Issue | Modified the OPC UA Client and OPC XML/DA Client tasks to set tag quality to BAD when the connection to the OPC Server is lost. |
5210 | Issue | Resolved an issue where the project security system did not verify that a client request had been processed before the next request was sent. This sometimes caused the project to become unstable, when the client received responses to requests that had timed out. |
5247 | Issue | Modified both the History-to-Text utility (HST2TXT.exe) and the built-in function Hst2Txt to improve their handling of Daylight Saving Time (DST). |
5292 | Issue | Resolved an issue that was causing project file tagl.txt to be deleted under certain circumstances. |
5313 | Issue | Resolved an issue with the "Built-in Dialogs Scale" setting (Project Settings > Web) where if it was set to anything other than 100%, it caused the "User Name" combo box in the "Log On" dialog box to be displayed incorrectly. |
5330 | Issue | Resolved an issue where an incorrect message was displayed when the project developer tried to insert the same System Symbol more than once. |
5351 | Issue | Resolved an issue where the built-in function GetOS would return incorrect values when called on Windows Embedded Standard. |
5377 | Issue | Resolved an issue with the built-in functions PrintWindow and SaveScreenshot where, if the functions were used to print or save a closed screen that contained a Trend Control object, the object was not printed or saved correctly. |
5378 | Issue | Resolved an issue where the run-time user could accidentally close the viewer on Windows Embedded if they clicked or tapped the top-right corner of the project screen. |
5392 | Issue | Resolved an issue where a screen file sometimes became corrupted if the project developer deleted an ActiveX control from the screen and then saved it. |
5455 | Issue | Resolved an issue with the Grid Control object where if it was configured to use Class Tag as its data source, it would show BAD quality for the wrong array elements. |
5616 | Issue | Modified the Protection Manager to allow you to select a MAC address when you change your softkey license. This is necessary because the license's site code is based on the computer's MAC address, and the computer may have more than one MAC address if it is connected to a VPN or otherwise using a virtual NIC at the time that you change your license. |
5634 | Issue | Implemented safeguards to prevent memory overflow errors that sometimes occurred when using TreeView Control (TreeView.ocx) in a project screen. |
5804 | Issue | Resolved issue with Remote Management experiencing timeout problems when downloading projects to remote computers when the Remote Agent is configured with users and passwords on its Security System |
5884 | Issue | Resolved an issue where the built-in function TagsDBAddTag would not accept new tag names beginning with the "@" character. |
InTouch Machine Editionv7.1 + Service Pack 3 + Patch 1 (Friday, July 04, 2014)
ID | Type | Description |
4864 | Change Request | Enhanced Studio Mobile Access (SMA) messages to precisely indicate when compression is enabled (unsupported) or when the screen is not published. Also added instructions to the error message explaining how to open the browser console to get additional information. |
3649 | Issue | Modified the Studio Mobile Access (SMA) Thin Client interface to support connection to the server through routers. |
3929 | Issue | Modified the Alarm/Event Control object to sort messages properly by Date/Time, even when the historical data is saved in an external database. |
4349 | Issue | Modified the label ""Extern Translation"" to ""Enable Translation"" on the ""Object Properties > Messages"" dialog of the Smart Message object (on the development environment) for consistency. |
4374 | Issue | Resolved issue with a form being displayed by the Studio Service Tray in some systems |
4386 | Issue | Modified the graphic interface to support data entry for objects with mnemonics even when the ""Use popup input for text objects"" option from Project >> Settings >> Viewer is enabled (checked). |
4426 | Issue | Modified the Driver task to support writing floating point (real) values with precision beyond the 6th decimal digit for drivers that handle real values as string |
4509 | Issue | Resolved issue with the Text Object alignment of text being ignored when using the translation tool to switch to a different language during the runtime |
4557 | Issue | Modified the Collaboration Server to make sure that the tags database main file (Tagl.txt) is converted to XML format when applicable, in order to avoid errors. |
4585 | Issue | Modified the Tag Integration for the ""AutomationDirect Koyo"" provider to support CSV files with ""unassigned items"". |
4680 | Issue | Modified the OPC DA/XML task to recognize the data type of items that were not ""available"" for the OPC Server when the OPC DA/XML Client task was launched, but eventually become ""available"" (e.g.: connect the device to the network only after the OPC DA/XML task was launched). The new algorithm allows the OPC DA/XML Client to recognize the data type of items that become available during the runtime and, consequently, be able to write values to such items. |
4681 | Issue | Improved the performance of the Tag Integration for the ""RSLogix 5000 family"" provider when loading tag names from the L5K file. Moreover, the Tag Integration was modified to ignore ""Encoded Data blocks"" while importing the remaining tags available in the L5K file. |
4728 | Issue | Modified the Trend Task to avoid missing samples when the format of the Trend worksheet(s) was set to Proprietary (*.hst files). |
4752 | Issue | Modified the OPC XML/DA Client task to indicate bad quality for the tag(s), if any, associated with a blank or invalid item, while communicating properly with the remaining items properly configured in the same OPC XML/DA Client worksheet. |
4753 | Issue | Modified the OPC XML/DA Client task to recognize changes implemented in the OPC XML/DA Client worksheets and saved while the task was running - online configuration. |
4766 | Issue | Modified the TCP/IP Server to handle legacy alarm controls asynchronously, preventing possible system errors |
4770 | Issue | Modified the Collaboration server to prevent it from displaying error messages when editing tags in a project without any classes (Project Explorer > Global > Classes). |
4843 | Issue | Modified the ImportXML built-in function to handle the size (height and width) of polygons properly and avoid settings unexpected values for the object width when editing it with the development environment (screen editor) after importing the screen(s). |
4890 | Issue | Resolved issue with the tag quality remaining Uncertain after the user attempted to enter values out of the configured min and max range |
4942 | Issue | Resolved an issue with the alignment of Text objects in the screen worksheet, when the Text Data Link animation was applied to the objects and the Auto Size option was enabled. |
5081 | Issue | Corrected the Studio Mobile Access log system that was reporting a wrong line number when a script had a VBScript code line break (""_"" character) inside a VBScript comment. |
5101 | Issue | Modified the Trend Control to display the pens in Online Mode, even if the values are saved in an external database with TimeStamp set to Local Time (not UTC). |
5116 | Issue | Resolved issue with disabling all objects that can receive focus in a screen during the runtime could cause unstable behaviors |
5181 | Issue | Update OPC OpenSSL to the latest version to address CCIRC Advisory AV14-031 OpenSSL vulnerability |
5184 | Issue | Modified the Trend/Alarm database interface to prevent 100% CPU usage when inserting data on relational databases |
5197 | Issue | Modified the asynchronous database insertion algorithms to prevent instability that could cause system errors |
5213 | Issue | Improved the Studio Mobile Access (SMA) script error information to allow better identification of the script that is preventing the screen from opening. |
5215 | Issue | Improved the Studio Mobile Access to support the VBScript code ""If $Tag Then $Function() Else $Function() End If"" all in the same line. |
InTouch Machine Editionv7.1 + Service Pack 3 + Patch 7 - Known Issues (Wednesday, October 07, 2015)
ID | Type | Description |
1748 | Issue | Import Wizard does not import Opc Ua, Opc Xi and Tag Integration configuration files [WORKAROUND]: Copy the Opc Ua, Opc Xi, and Tag Integration settings manually from the source project. |
2033 | Issue | CEServer for EmbeddedView v7.0 does not properly handle when there is a MAC ID in the Registry [WORKAROUND]: The workaround is to manually clear the following registry key: This is the Registry Key: SYSTEM\\CurrentControlSet\\Control\\Class\\{4D36E972-E325-11CE-BFC1-08002bE10318} |
2134 | Issue | Validation of the Custom Resolution fields happen when creating new projects even if you have selected one of the pre-defined resolutions [WORKAROUND]: Change the resolution back to Custom and write a value between 240 and 10000 on both fields. Then, choose one of the pre-defined resolutions on the Combo box |
2534 | Issue | The Mobile Access legend is not properly redrawn on some specific conditions [WORKAROUND]: Toggle the cursor to for the legend redraw |
4821 | Issue | If you modify a tag field that applies to the entire array Mobile Access will not synchronize the value to all the array elements [WORKAROUND]: Because the field has the same value for all indexes, you should use one index for all the locations where you need the field. |