====Resolved Issues - Wonderware InTouch HMI 2014 R2 (v11.1) Patch 01==== | ====Resolved Issues - Wonderware InTouch HMI 2014 R2 (v11.1) Patch 01==== | ||
InTouch HMI 2014 R2 (v11.1) Patch 01 resolves the issues listed in the following table. These issues are listed by their Change Request (CR) number and any assigned Service Request (SR) number. The left column of the table shows the original Change Request in which the issue was identified. The Related Change Requests column shows other subsequent change requests that are related to the original change request. | InTouch HMI 2014 R2 (v11.1) Patch 01 resolves the issues listed in the following table. These issues are listed by their Change Request (CR) number and any assigned Service Request (SR) number. The left column of the table shows the original Change Request in which the issue was identified. The Related Change Requests column shows other subsequent change requests that are related to the original change request. | ||
+ | |||
+ | |||
{| border="1" width="1055" cellspacing="2" cellpadding="5" | {| border="1" width="1055" cellspacing="2" cellpadding="5" | ||
| style="text-align: center;" bgcolor="#87D300" width="35" | <span style="color: #000000;">Original Change Request</span> | | style="text-align: center;" bgcolor="#87D300" width="35" | <span style="color: #000000;">Original Change Request</span> | ||
Строка 757: | Строка 759: | ||
| <b>SR103134223</b>: The GetPenValX2 method was not available in the .NET version of the ArchestrA Trend control. | | <b>SR103134223</b>: The GetPenValX2 method was not available in the .NET version of the ArchestrA Trend control. | ||
|} | |} | ||
+ | |||
====Wonderware Historian Client 2014 R2 (v.10.6) Patch 01==== | ====Wonderware Historian Client 2014 R2 (v.10.6) Patch 01==== | ||
*Last revision: 5/15/2015 | *Last revision: 5/15/2015 |
Версия 17:07, 21 июня 2015
Содержание
- 1 Состав
- 1.1 Path 01
- 1.1.1 Resolved Issues - Wonderware System Platform 2014 R2 Patch 01
- 1.1.2 ArchestrA Service Bus and Multi-Galaxy Communication Issues
- 1.1.3 Resolved Issues - Wonderware Application Server 2014R2 Patch 01
- 1.1.4 Wonderware Historian Server 2014 R2 (version 11.6) Patch 01
- 1.1.5 Resolved Issues - Wonderware InTouch HMI 2014 R2 (v11.1) Patch 01
- 1.1.6 Wonderware Historian Client 2014 R2 (v.10.6) Patch 01
- 1.1 Path 01
Состав
- Wonderware InTouch HMI 2014 R2 (v11.1)
- Wonderware Application Server 2014 R2 (v4.1)
- Wonderware Historian Server 2014 R2 (v11.6)
- Wonderware Historian Client 2014 R2 (v10.6)
- Wonderware Information Server 2014 R2 (v5.6)
Path 01
Resolved Issues - Wonderware System Platform 2014 R2 Patch 01
This section documents important resolved issues in Patch 01. The issues listed here are broadly categorized as Wonderware System Platform-level issues. This list is not comprehensive. Additional resolved issues are documented in the product-specific Readme files.
ArchestrA Service Bus and Multi-Galaxy Communication Issues
L00132684: | SR 48910422: Logging in to InTouch with OS Group based security enabled for the Galaxy required an extended amount of time. | |
L00136063: | SR 103133804: The configuration window for the ASB OPCUA Client disappeared when connecting to an Automation OPC UA Server. | |
L00136605: | SR 33913773: InTouch managed applications were not activating all items from an OPC UA Server. |
Resolved Issues - Wonderware Application Server 2014R2 Patch 01
This section describes issues that have been resolved in Wonderware Application Server 2014R2 Patch 01. These issues are listed by their Change Request (CR) number and any assigned Service Request (SR) number. The left column of the table shows the original Change Request in which the issue was identified. The Related Change Requests column lists subsequent change requests that are related to the original change request.
Original Change Request | Related Change Requests | Description |
---|---|---|
L00119440 | L00133653
L00134710 |
SR 103124254: Recreating a Galaxy from the cab file created redundant folders of deployed InTouch Applications on the Galaxy Repository. |
L00120671 | L00132022 | SR 31711844; SR 48910371: A message was displayed that the OPCClient Target node could not be found. |
L00126108 | L00136278 | SR 10916638: Objects could not be configured, deployed, or undeployed with customer GPO enabled due to insufficient permissions in the objects "...\CheckedIn" and "...\CheckedOut" folders. |
L00126276 | L00131581 | SR 37113036: The description could not be defined for the scan group item error count alarms (scangroup.ItemErrorCntAlarm.DescAttrName). |
L00129452 | L00136409 | SR 103128626; SR 103134169: Entering a DeadBand Value in the Field Attribute tab did not have any effect. |
L00129575 | L00132211 | SR 103129209; SR 103131806: After importing a package file that contained area objects, some graphic files were missing. |
L00130392 | L00132202 | SR 103129988; SR 103132058: A user could not gain access using a Smart Card and received the message, "User does not belong to any of the configured Roles." |
L00130716 | L00135193 | SR 19818424; SR 10417719: If a corrupted symbol was embedded in an object, it disabled the Symbol Editor. |
L00131155 | L00132335
L00135132 |
SR 44710384; SR 12613067; SR 103133171: The System Communication failure alarm was activated even though no failure occurred. |
L00131405 | L00131406 | Importing an InTouch View Application into a lower product version from a higher product version caused WindowMaker to stop. |
L00131545 | L00135690
L00135691 |
SR 40215477: Using an RDP connection caused some values in an InTouch window to freeze. |
L00131579 | L00135191 | SR 15317217; SR 10417719: Field Attributes occasionally remained in the initializing state, even when a script was trying to interact with the attribute. |
L00131583 | L00132245
L00132302 L00132356 L00134797 |
SR 38910487; SR 19818538; SR 50810081; SR 22210159: MessageChannel GetTickCount rollover was causing connection reset and failovers. |
L00131713 | L00132744
L00133823 L00134320 L00136190 |
SR 103131703; SR 49910007; SR 43110490: The Pending Change icon was shown for InTouch View applications, even though no changes had been made. |
L00131752 | L00131885 | SR 51010032: When performing a CSV Galaxy load, an erroneous message about missing attributes in an object was displayed instead of an acknowledgement that the object had successfully loaded. |
L00131793 | SR 48910335: An error message was logged from WWCdi after checking in a template, stating that an invalid length parameter was passed to the RIGHT() function. | |
L00131844 | L00132800 | SR 43110407; SR 49410030: Platform names shorter than 14 chars were not displayed in the System Management Console log navigation tree. |
L00132179 | L00135192 | SR 37113270; SR 10417719: The aaEngine sometimes failed to register reference calls, and valid references appeared with an invalid status. |
L00132255 | L00132348
L00132797 L00134890 |
SR 45110495; SR 47910035; SR 49410030: Importing an object into a previous version of Application Server worked with no errors or warnings, and resulted in some DLL files being changed. |
L00132477 | SR 22318648: Two systems were successfully time synchronized after drifting out of synchronization, but an excessive number of messages were reported to the OPC client. These messages were benign, but had the potential to fill the log. | |
L00132976 | SR 52310005: When an object was deployed on a system running Microsoft Windows Server 2012, the AppEngine stopped working. | |
L00133054 | L00133143
L00133144 |
SR 49410032: When an object with the same tagname, container and contained name was created via a Galaxy load, the object could not subsequently be edited or deleted. |
L00133154 | SR 103132532: If a string UDA was empty, zero would be inserted into the Value or CheckValue columns of v_EventHistory. | |
L00133173 | Creating a Galaxy did not succeed when Application Server was running in a VM on Microsoft Azure. | |
L00133458 | L00134674 | SR 103132521; SR 37510653: When provisioning was performed using the ArchestrA WorkFlow object, it slowed down the response time of the object. |
L00133478 | SR 22318522; SR 103130791: A Field Attribute did not show the correct value for the PLC unless the Buffered Data option was enabled. | |
L00133482 | L00134870 | SR 46110712; SR 103133232: The value of AppEngine attribute, Scheduler.InputQueueSizeAvg, was increasing over time. |
L00133521 | L00135441 | SR 43110404: The auto-synchronize tags setting did not synchronize correctly when new tags were added, and objects with references to the new tags did not work. |
L00133674 | L00134613 | SR 103134125; SR 49010033: Remote node deploy failed after Application Server was upgraded. |
L00133708 | L00133709
L00133710 |
SR 43110414; SR 43110417; SR 49410052: A remote GR was occasionally unable to connect to the Application Server IDE, and platform status was listed as unavailable in Platform Manager. |
L00134423 | When multiple objects that use I/O auto assignment were imported, warnings about unresolved I/O references for some of the imported objects were sometimes displayed in error. | |
L00134427 | During installation of a product that embeds the 2014 R2 version of ASB, Application Server would, depending on its version, either lose configuration, or always show as configured. | |
L00134499 | SR 44710488: Object Viewer displayed incorrect values with Bad data quality for some Input.Value attributes and timeouts would occur. | |
L00134677 | SR 51510460: While upgrading, platform deployment to a remote node failed. | |
L00134704 | L00134850 | SR 43110446: Redundant AppEngines stopped operating if the backup platform and AppEngine were not deployed. |
L00134713 | SR 20611434: Access was denied, and repeated error messages were logged from component ObjSyncMgr. | |
L00134716 | SR 38910496: When the QueryObjects method was executed, the CommandResult always returned TRUE-SUCCESS. | |
L00134955 | SR 103133241: In the Chinese version of InTouch, a Situational Awareness Library symbol did not display in published applications. Instead of the symbol, the message "Graphic not available" was displayed. | |
L00135002 | L00136015
L00136605 |
SR 103133094; SR 33913773; SR 23314780: InTouch managed applications were not activating all items from an OPC UA server.
Important: If you are using an OPC UA client with Wonderware System Platform (WSP) 2014 R2 P01, you must apply HotFix CR L00136605. WSP 2014 R2 P01 includes fixes to Application Server for this issue, but OPC UA client is a separate installation and is not included in the patch. |
L00135073 | The descriptions and Eng Units settings of inherited attributes were deleted when a new attribute was added to the parent template or a different attribute was deleted from the parent. | |
L00135076 | L00135326 | SR 43110442: After Galaxy validation, the Operations view did not sort objects correctly when the Status column was used for sorting. |
L00135117 | SR 43611211: After a reboot, one node was not able to see alarms from other nodes. | |
L00135136 | SR 19713757: Multiple concurrent terminal service users were sometimes unable to connect to the Application Server IDE, and an error message stating that the clients could not be synchronized would be displayed. | |
L00135254 | SR 103133437: Redeploying an object did not clear the Galaxy status flag that indicated that there were pending changes. | |
L00135424 | SR 51010321: Choosing the Repair option from Setup changed the watermark for the Application Server IDE from 2014 R2 to an older version. | |
L00135466 | SR 54010002: When using a Redundant AppEngine with an undeployed and unassigned partner, the following error was generated on each scan: "EventHistorizationShim SetHistorianDetail: System.Exception: SetRedundantSFMode call failed, error: Server name length invalid" | |
L00135553 | SR 52410087: Reassigning objects in the IDE took longer than expected. | |
L00135651 | SR 54010003; SR 45110540: During failover, the Logger listed an access violation for some engines. This could lead to other error messages, including communication errors, failure to connect to the standby platform for store/forward, and failure to get store forward redundancy attributes from engine. | |
L00135684 | SR 52410673: An analog field attribute reading a double word from a PLC, with the first bit modified as a signed bit, would display 0 in Object Viewer instead of the actual value in the PLC double word. | |
L00135872 | SR 103134042: Attribute descriptions in derived templates were lost when a change was made to the parent template. | |
L00135926 | Changing one object sent all application objects that referenced the changed object into a warning state. To remove the warning state, the objects required manual validation. | |
L00136014 | SR 51010375: Float attributes that used scaled Integer inputs were rounded. | |
L00136048 | SR 31712856: A new Galaxy based on a backup cab file could not be created if the Galaxy name was 12 characters or longer. | |
L00136054 | SR 103134004: The data quality for field attributes configured as Boolean or float occasionally did not update correctly. | |
L00136110 | SR 103133825: Data change events for analog and Boolean area attributes were not being recorded in Historian and were instead triggering a warning in the log. | |
L00136169 | SR 10417772; SR 103134440: After migrating a Galaxy from a previous version to Wonderware Application Server 4.1 (2014 R2), some objects were not displayed in the Model and Deployment views of the IDE. | |
L00136251 | SR 103134082: ArchestrA Graphics disappeared from WindowMaker or WindowViewer after working correctly for a period of time. | |
L00136227 | SR 103134493: Entering an IP address instead of node name was accepted for the Time Master node, which would then cause the Galaxy to stop. | |
L00136496 | SR 103134462: The object description was propagated to the Historian, instead of the field attribute description, when the object or field attribute description was changed and the change was deployed. |
Wonderware Historian Server 2014 R2 (version 11.6) Patch 01
- Last revision: 5/27/2015
This Readme provides information about Wonderware® Historian Server 2014 R2 (version 11.6) Patch 01.
For information about new features, hardware and software requirements, product compatibility, installation and upgrades, and user documentation, see the ArchestrA® System Platform Readme, which is located in the root folder of the ArchestrA System Platform installation media.</p>Resolved Issues In This Patch
This section describes issues that have been resolved in Wonderware Historian Server 2014 R2 Patch 01. These issues are listed by their Change Request (CR) number and any assigned Service Request (SR) number. The left column of the table shows the original Change Request in which the issue was identified. The Related Change Requests column lists other change requests that are related to the original change request.
<p class="tableheader" style="text-align: center;">Original Change Request | Related Change Requests |
Description |
L00131591 |
SR 103130911: Historian Server 11.0 returns incorrect data from legacy history blocks. | |
L00131603 |
SR 14812687: The following error message appears in the Logger: "Tag xxx.yyy failed to add historian after 3 attempts." | |
L00131680 |
L00131001 |
SR 10916964: Ported hotfix L00131001 to Wonderware System Platform 2014 P1 for "Value validation failed" errors to Historian 11.5 P1. |
L00131718 |
SR 192111219: After a period of time, a subset of tags are reporting quality status as "IDAS overflow recovery." | |
L00131946 |
SR 14812717: Some replication tags are not being updated in the tier-2 historian. | |
L00132025 |
L00131589 |
SR 48910372: In the Historian SDK 2012, the GetTagInfoByName() does not return the tag key that can be used to restore values. |
L00132159 |
SR 45510703: Events sent from Application Server are failing when the description text contains a new line or non-printable character. | |
L00132256 |
L00131603, L00132373 |
SR 22210152, SR 51310087, SR 51310145: This error message is displayed: "StartDataRetrievalQuery failed (MDAS handle; Error code; Tag count; Query handle)" and LogViewer has several messages requiring analysis. |
L00132380 |
SR 10917005: In Historian 11.0 P1, local summary replication data is buffered and not back-filling. | |
L00132535 |
L00131201 |
SR 14413867: Porting L00131201 to Wonderware Historian 2014 R2 P1. |
L00132687 |
After installing Historian 11.0, an error message displays in the SMC: "Server database version incompatible with this client version, Configuration Editor disabled.Fatal initialization error - unable to start. (Failed to open connection to configuration database)." | |
L00132841 |
SR 52310001: Historian Server generates very large history block (store-and-forward) files. | |
L00132866 |
L00123102 |
SR 103132443: Fixed improper handling of history block patch, where this message was generated in SMC: "Client access point (StoreOriginalStreamValues for session <ID> returns error: error = 81 (Blocked by disk management)) [MPSDM01; HistStorageConnection.h; 290]." |
L00133338 |
SR 51810059: Executing an UPDATE statement using OPENQUERY causes this error: "ERROR: MDASOpen returned error code (1;error = 85 (Unknown exception))." SELECT * FROM OPENQUERY(INSQL, 'UPDATE History SET Value = 0, QualityDetail = 192 WHERE ... | |
L00133365 |
SR10916887: In Historian 11.0 P2, storage data is being written into wrong history block. | |
L00133551 |
SR 49410046: In Historian 11.0, can't retrieve data from Trend, Query, and SQL. Also, a message about OLE access is generated. | |
L00134015 |
SR 10917083: In Historian 10.0 SP1 P1, an event tag scheduled for daily is creating an event hourly. | |
L00134330 |
L00134384 |
SR 45711194, SR 10313074, SR 103132904: FastLoad ended unexpectedly with errors. |
L00134392 |
SR 45711187: In Historian 11.0, replication stops replicating data for some tags. To address this, TraceSubscribeTags trace ability was added. | |
L00134497 |
SR 39911126: The Historian Client Trend display is sometimes showing incorrect traces. | |
L00134736 |
SR 50410263: Queries are run, but do not finish. Also, aahStorage.exe is consuming 80-94% of the CPU. | |
L00134796 |
SR 103133212: When tags are imported with alarms from InTouch, the alarm limits type is always "Up." | |
L00134897 |
SR 45711223: This message appears in the Logger: "Main storage failed to find history block." | |
L00134948 |
SR 46111026, SR 103132164: An error occurred and the log file is flooded with these messages: "Client access point (StoreOriginalStreamValues for<ID>: last error = 1460. (This operation returned because the timeout period expired.)" and “Client access point (Tag information not found for id)." | |
L00135048 |
SR 48910569: The aaEngine component of the SMC Logger displays this message to indicate an exception: "CListenEventProxy::RaiseEvent failed: System.Exception:RaiseEvent failed" | |
L00135128 |
SR 52410191: In silent mode, aahITTagImporter does not import tags when an InTouch node already exists. | |
L00135439 |
SR 51310431: Old history blocks from 2002, 2003, and 2004 cause this warning: "Overlaps in time with another block." | |
L00135651 |
SR 54010003, SR 45110540: There was an access violation on failover, failing to get StoreFwdRedundancyTCPPort attributes from the engine. Issues reported include: "Engine failover not reliable" and "some ETCs report <none> for alternate historian." | |
L00135829 |
SR 50410338: After an IDAS reconnects to the historian, slow-changing tags that are configured to use cyclic storage are not updating properly. | |
L00136022 |
SR 48910620: The Historian SDK does not connect with a domain user account. |
Resolved Issues - Wonderware InTouch HMI 2014 R2 (v11.1) Patch 01
InTouch HMI 2014 R2 (v11.1) Patch 01 resolves the issues listed in the following table. These issues are listed by their Change Request (CR) number and any assigned Service Request (SR) number. The left column of the table shows the original Change Request in which the issue was identified. The Related Change Requests column shows other subsequent change requests that are related to the original change request.
Original Change Request | Related Change Requests | Description |
L00109132: | L00135053, L00135176, L00135283 | SR 103133305: After migrating an InTouch application from version 8.0 to 11, the text font shown on button graphics changed from System to Tahoma. |
L00114924: | L00131488, L00132071 | SR 12611813: If ArchestrA security was selected for a managed application from the Galaxy and InTouch, the $AccessLevel system tag was reset to 0 when an attempt was made to change the password with an action script triggered when $ChangePassword = 1 and contained the $OperatorEntered and $PasswordEntered system tags. |
L00116543: | L00133546 | SR 33811790: ShowSymbol scripts interfered with updates to an Embedded Alarm Client Control with any version of the Windows 2008 operating system. |
L00122388: | L00131431, L00131461, L00131960, L00132427 | SR 38812110: The value of a tag did not get updated if there was an overlap with a Combo Box Windows control. |
L00122952: | L00132312 | SR 24515708: An Alarm DB Logger error message "The statement has been terminated. String or binary data would be truncated." occurred when the alarm buffer did not empty. |
L00123461: | L00135018 | SR 10417006: A Remote reference (RTR) used for input animation showed an "illegal character in name" error message if an item name included a space, even if the name was enclosed within quotes (ACCESSNAME:"item name"). |
L00123465: | L00134514, L00135203 | SR 41810078: An application window could not be moved between dual monitors during run time if it contained an ActiveX control developed with Visual Basic 6. |
L00123501: | L00125532, L00136382 | SR 33913166: Switching the language of an InTouch application to a language other than the application's base language caused the mouse cursor to flicker. |
L00124290: | L00126183, L00126298, L00130128, L00134742 | SR 103127184: An orange icon appeared in the ArchestrA IDE when deploying an InTouchViewApp instance. |
L00124372: | L00134768 | SR 33112633: Settings from the Windows Win.ini file located in the user's profile directory were not used when WindowViewer was started on a computer running Windows Server 2003 R2. |
L00128765 | L00129312, L00133864, L00134090, L00134794 | SR 45510819, SR 33913707: A selection halo remained around an ArchestrA action button after moving the mouse cursor off of the button. |
L00129332 | L00132002 | SR 103129417: Descriptions of Factory Alarm appeared corrupted if localized to a language requiring multi-byte characters, such as the Cyrillic character set. |
L00130122 | L00131537, L00132513 | SR 22210102: If a Windows short cut was used to start an InTouch application in WindowViewer with the Prompt user to restart WindowViewer option selected for the NAD Change Mode feature, the application updates from the NAD server were not implemented on the client nodes after restarting WindowViewer. |
L00130285 | L00130357, L00132824 | SR 12612924: After upgrading to InTouch HMI 10.6.001, a Historical Trend display showed data in periods in which no data was collected. A Historical Trend display should show black gaps in the trend line to indicate periods without data within the trend interval. |
L00130543 | L00133726 | SR 103129417: If WindowMaker was installed on a Virtual Machine (VM) running VMware Tools ESXi 5.0 that has not been upgraded to 'Update 2', WindowMaker became unresponsive when trying to save an InTouch window or other application-related data files. The source of the problem was a known issue with the vShield Endpoint filter driver that ships with VMware Tools ESXi 5.0. This driver is automatically loaded when VMware Tools is installed using the Full option, rather than the Typical default. If this problem is encountered while working within WindowMaker, it is possible that portions of the InTouch application may become corrupted because not all data is saved and the states of some application files are left unresolved. |
L00130698: | L00131114, L00131297, L00131529, L00132173, L00132295, L00135775 | SR 103130881: When the Alarm Client control was configured to query alarms from multiple backup pairs, the configured text and background colors of the Alarm Client were lost during run time. The colors reverted to black text on a white background for all types of alarms. |
L00131374: | L00133124 | SR 10417554: At run time, graphics using color animation to represent machine state did not update consistently. Also, graphics containing Value Display animation did not show complete analog values. Users were forced to refresh the application window to update the symbol's color and Value Display animations. |
L00131522: | L00131600 | Importing an ArchestrA symbol using the programmatic API utility failed with a schema error after changing the symbol's original relative anchor point. |
L00131744: | L00135221 | SR 40216125: The border color of the History Trend covered the entire trend surface after using the scooter control to update the current time. |
L00131814: | L00131593 | SR 42010101: WindowViewer experienced memory shortages because of maximum allocations observed from UDDetailedHandleData, which was leaking global memory. |
L00131828: | L00131960, L00132576, L00132589, L00132801, L00133044, L00134708, L00135985 | SR103130881: The IASGrid was not getting refreshed with new values after the user selected the Block button. Closing and re-opening the graphic hosting the grid resolved the problem. |
L00132078: | L00132967 | In version 10.6 of InTouch, open pop-up windows with embedded graphics did not close automatically after the main application window was closed in WindowViewer. |
L00132278: | L00133618, L00133791, L00135214 | SR 103132125: Lagging movement or delays were observed in the ArchestrA Graphic Editor when using a mouse to select multiple graphic objects placed on the canvas. The delays were observed when Wonderware System Platform 2014 was installed on computers running Windows 8.1 or Windows 2012 R2. |
L00132372: | L00134645 | SR 45110418: After migrating an InTouch stand-alone application from version 10.5 to version 10.6 Patch 01, some users were missing if there was a mismatch between the number of listed users and passwords in the Password.bin file. |
L00132409: | L00133159, L00133160 | SR 51010070: Opening a graphic with an embedded Trend pen control with either the ShowGraphic function in a script or ShowSymbol animation was delayed up to 15 seconds based on the number of pens recording historical data. |
L00132496: | L00132860, L00132908, L00136095 | SR 15618685: New domain users could not log on with their Windows user credentials to an InTouch application secured with operating system-based security. |
L00132598: | L00136134 | SR 49110209: Alarms from an area did not display after changing the query to another area because the FilterCriteria was not getting set when setting an alarm query from an ActionScript without opening the QueryFilter tab at least once. |
L00132633: | L00133273, L00133321 | SR 49810012: WindowMaker closed or became non-operational after committing changes to a SmartSymbol with multiple instances of the SmartSymbol placed in many application windows. |
L00132637: | L00133772 | SR 103132265: After the user selected an alarm filter, all alarms remained visible for several seconds before the filtered view showed only the matching alarms. |
L00132654: | L00133368 | SR 103132359: The UserDefined1 Element Style located in the ArchestrA Galaxy Style Library did not apply the selected gradient fill during run time. A warning message appeared in the SMC log. |
L00132733: | L00133182 | SR 103132375: The ScaleAutoPen() function in an action script did not automatically scale a measured value within the range of a TrendClient control if the script was invoked after trend's initial duration. Values could be scaled correctly only if the script was run within the trend's initial duration. |
L00132903: | L00134328, L00134466 | SR 103132407: InTouch would be delayed by up to 20 seconds when a user logged in with OS security and the primary domain controller was inactive. |
L00132905: | L00135092, L00135181 | SR 43911243 SR 103132453: After migrating a Galaxy from Wonderware System Platform 2012 R2 P01 to Wonderware System Platform 2012 R2 P02, some ArchestrA graphics showed a red X and failed to display with a warning message in the Logger that "OwningObject Change: failed to get new tagname from the hierarchical name." |
L00132907: | L00133597 | SR 22210155: Creating an Alarm Database and using stored procedures to grant permission to database tables and views failed when the connected user logged on as wwAdmin, wwPower, or wwUser. The stored procedures failed because the connected user was attempting to grant permissions to all defined database user roles. |
L00132932: | L00133998, L00134518 | SR 103132494: The Alarm Client Control was unable to acknowledge alarms after a failover. |
L00132959: | L00133789, L00133958 | SR 52310013: A .NET-control with an embedded custom WPF control would freeze after switching windows several times. This behavior occurred when the WindowViewer "in Memory Caching" configuration option was selected. |
L00133071: | L00133740, L00134010, L00135146, L00135147 | SR 103132441: The AlarmClient.QueryFilters.DefaultFilter.FilterCriteria function did not work after an upgrading from Wonderware System Platform 2012 R2 to Wonderware System Platform 2012 R2 Patch 01. |
L00133145: | L00134347 | SR 50310189: Shutting down a computer while WindowViewer was running caused the computer to hang with an error message that WindowViewer was "preventing Windows from shutting down". |
L00133267: | L00133790 | SR 48910456: Alarm acknowledgement comments in the Alarm Control were prefixed with a "Std Ack" comment. |
L00133276: | L00135398, L00135418 | SR 49910067: After upgrading from InTouch 10.1 to 10.6 Patch 02 on Windows Server 2008, user log on attempts failed on one terminal server node, while succeeding on other nodes. |
L00133297: | L00134711, L00134770, L00134784, L00135094, L00135777 | SR 22210163: WindowViewer leaked large amounts of memory with windows caching disabled. |
L00133386: | L00133744, L00133989 | SR 45110459: Editing an existing Accessname during a failover resulted in losing the existing failover condition in some cases. |
L00133408 | L00134345, L00134545 | SR 50310189: The SMC shows logging event failures when the string length of tagname's description in LogDataChangeEvent() method exceeded 271 bytes and the description was in a unicode character language. |
L00133427: | L00134919, L00134942 | SR 103133256: The gradient frame of an ArchestrA graphic element did not display properly in run time. |
L00133430: | L00133619 | SR 51010175: A pop-up window containing ArchestrA graphics that was opened with a ShowSymbol script did not close with the parent window when the parent window was closed with a replace action called from a datachange script. |
L00133454: | L00134943 | SR 103132525: InTouch WindowViewer became non-operational occasionally when the wrong password was entered. |
L00133713: | L00134350, L00134393, L00134673 | After applying Hot Fix L00130272, WindowViewer required 100 percent CPU utilization. |
L00133809: | L00134311, L00134574 | SR 103132723: An InTouch application name that started with the letter "L" could not be started with a keyboard short cut. |
L00134085 | L00135375 | SR 45510818: An InTouch application became non-operational after placing the History Trend w/Scooters and the Trend/Zoom/Pan Panel wizards in a window localized to German. |
L00134332 | L00134836, L00134952 | SR 103132839: Historical alarm translations did not appear in the Alarm Client Control after changing the application language during run time. |
L00134529: | L00134765, L00135211 | SR 44510511: Importing a localization XML with InTouch Managed application text failed with a logged message that the file was not a valid XML file. |
L00134654: | L00135182 | SR 103132946: The Alarm Client Control did not show the correct time zone for historical alarms. |
L00133713: | L00134673 | After applying hot fix L00131431, an application running in WindowViewer required 100 percent CPU utilization. |
L00134767: | L00135396 | SR 103133104: After migrating a Galaxy from WSP 2012 R2 to 2014, symbols looks different in the ArchestrA graphic editor, WindowMaker, and WindowViewer. Graphic elements in symbols showed slight misalignment. |
L00134770: | L00134532, L00134567, L00134577, L00135059 | SR 22210163: WindowViewer consumed memory when the cache was enabled and graphic symbols were opened and closed using ShowSymbol animation. |
L00134844: | None | SR 103133169: Online help was unavailable within the Edit Symbol Scripts dialog box. A message appeared in the SMC log "Warning ArchestrA.IDE.Common Help window has not yet been created." |
L00134951: | L00134309, L00135066 | SR 46510316: When a non-existent InTouch tag was bound to an indirect variable for the first time, a "nonexisting_tag" error appeared in the Logger. When binding the same non-existent tag again, attributes of the indirect variable did not update. |
L00134955: | L00135640 | SR 103133241: In the Chinese version of InTouch, a Situational Awareness Library symbol did not display in published applications. The message "Graphic not available" was displayed instead of the symbol. |
L00134992: | L00135256 | SR 50610147: When using Danish alphabetic characters (for example: Æ, Ø or Å) in ArchestrA Area objects, alarms did not appear in the Alarm Control client. |
L00134993: | L00136005, L00136006 | SR 49910134: After changing an alarm group query in the Tagname Dictionary, the Tagname Dictionary window disappeared and the changes could not be saved. WindowMaker had be closed from Windows TaskManager. This issue was specific to running InTouch with a 4 monitor configuration and did not occur using a single monitor. |
L00135036: | L00135151 | SR 103133262: When alarms were acknowledged using the ArchestrA Alarm Client control, the OperatorNode field did not get populated. When alarms were acknowledged using the InTouch AlarmViewerCtrl (ActiveX control), the OperatorNode field was populated correctly. |
L00135098: | None | After installing InTouch Version 11.0 and Patch 01, text did not redraw correctly when multiple text boxes overlapped each other. |
L00135158: | L00135228, L00135314 | SR 103133410: Recipe manager scripts returned an error code of 0 when they could not access a recipe file. |
L00135183: | L00135222 | SR 103133435: The Embedded Alarm Client control refreshed the display twice in succession after changing a alarm query filter. |
L00135298: | L00135419 | SR 103133456: The Tab key did not work after the user clicked a button associated with the EnableDisableKey function and pressing the Ctrl+Alt+Del key combination. |
L00135312: | L00135852, L00135957 | SR 49910144: An invalid reference on an object attribute was received when a symbol was embedded several times. |
L00135386: | L00135585 | SR 40710052: A managed InTouch application produced a SMC log message when acknowledging alarms "CUserAuthenticator::IsSecurityEnabled--Using hard-coded "MyGalaxy" as Galaxy name. |
L00135415: | L00135612 | The ArchestrA Alarm Client experienced delayed response times in an InTouch Modern application. |
L00135423: | None | The online help from Wonderware System Platform 2014 R2 InTouch Application Manager or WindowMaker showed the message "*** BETA DRAFT - NOT FOR EXTERNAL RELEASE ***" in red. |
L00135475: | L00135618 | SR 41810305: When printing to a test file, windows with "#P" in the window name did not print correctly. The "#P" characters were replaced with empty characters or numbers. |
L00135477: | L00136053 | SR 41810319: Place holders were not removed when importing windows directly from an application folder. |
L00135478: | L00135679 | SR 41810344: Running HideSelf on a pop-up window closed other windows that should have remained open. |
L00135700: | L00135914, L00135939, L00135940, L00136090 | SR 41810363: When printing windows containing scripts, database entries, and link details to text files, random lines of Japanese text were missing from the printed output. |
L00135759: | L00136414 | 52410655: If the ShowGraphic method was called from a modeless window, the application's behavior differed when the user pressed the "Enter/Return" button or the left mouse key. |
L00135762: | L00135958 | SR 103134002: When converting standard InTouch windows to an ArchestrA Graphic from a Modern InTouch application, animations were lost if the window had cells. |
L00135830: | L00136031, L00136145 | SR 52410728: InTouch did not display Vietnamese characters correctly. |
L00135845: | L00135999 | SR 103134079: Fill animation did not appear correctly using the HorizontalPercentFill property set to 100 and the FillBehavior set to Horizontal. |
L00135876: | L00136285 | SR 103133579: The Embedded Alarm Client Control's GetItem method did not provide access to millisecond time stamp. |
L00135903: | L00136082 | SR 103134083: In an InTouch Modern application, closing WindowMaker also closed WindowViewer. |
L00135933: | L00136124 | SR 103134110: Graphics from instances in ArchestrA graphics could not be embedded. |
L00135948: | L00136179 | SR 43611481: After applying hot fix L00134340, acknowledging alarms deleted the alarm comments. |
L00136131 | L00136341, L00136580 | At run time, keyboard short cuts did not work properly from an input text box within a modal showgraphic pop up window. Typing the shortcut (i.e. Ctrl+A) in the text box showed the typed letter instead. |
L00136340: | L00136582 | SR103134223: The GetPenValX2 method was not available in the .NET version of the ArchestrA Trend control. |
Wonderware Historian Client 2014 R2 (v.10.6) Patch 01
- Last revision: 5/15/2015
- This Readme provides information about Wonderware® Historian Client 2014 R2 (version 10.6) Patch 01.</p>
For information about new features, hardware and software requirements, product compatibility, installation and upgrades, and user documentation, see the ArchestrA® System Platform Readme, which is located in the root folder of the ArchestrA System Platform installation media.
Resolved Issues In This Patch
This section describes issues resolved in the Wonderware Historian Client 2014 R2 Patch 01. These issues are listed by their Change Request (CR) number and any assigned Service Request (SR) number. The left column of the table shows the original Change Request in which the issue was identified. The Related Change Requests column lists other change requests that are related to the original change request.
Original Change Request |
Related Change Requests |
Description |
L00133279 |
L00134388 |
SR 10917057 - HistClient - Workbook - 10.5: In Excel, data from ManualAnalogHistory within "Value based criteria (narrow tables) with Wide Format" formulas returned as text rather than as numeric. |
L00132755 |
L00134389 |
SR 48910407: InTouch WindowViewer stops responding if you switch through windows that have HistorianClient Trend ActiveX control. |
L00133668 |
L00135371 |
SR 24412807: View.exe leaks memory and handles whenever a window with an Historian Client ActiveX control is opened or running. |
L00134981 |
L00135494 |
SR 51710015: Function MoveNextTag() does not work as documented. |